MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.3c04870

Медицинская библиотека · Analytical chemistry · 2024

Simultaneous Detection of Infectious Diseases Using Aptamer-Conjugated Gold Nanoparticles in the Lateral Flow Immunoassay-Based Signal Amplification Platform.

Kim Jinwoo, Baek Sowon, Nam Jungmin, Park Jeongeun, Kim Kihyeun, Kang Juyoung, Yeom Gyuho

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Various platforms for the accurate diagnosis of infectious diseases have been studied because of the emergence of coronavirus disease (COVID-19) in 2019. Recently, it has become difficult to distinguish viruses with similar symptoms due to the continuous mutation of viruses, and there is an increasing need for a diagnostic method to detect them simultaneously. Therefore, we developed a paper-based rapid antigen diagnostic test using DNA aptamers for the simultaneous detection of influenza A, influenza B, and COVID-19. Aptamers specific for each target viral antigen were selected and attached to AuNPs for application in a rapid antigen diagnosis kit using our company's heterogeneous sandwich-type aptamer screening method (H-SELEX). We confirmed that the three viruses could be detected on the same membrane without cross-reactivity based on the high stability, specificity, and binding affinity of the selected aptamers. Further, the limit of detection was 2.89 pg·mL-1 when applied to develop signal amplification technology; each virus antigen was detected successfully in diluted nasopharyngeal samples. We believe that the developed simultaneous diagnostic kit, based on such high accuracy, can distinguish various infectious diseases, thereby increasing the therapeutic effect and contributing to the clinical field.

Для цитирования: Kim Jinwoo, Baek Sowon, Nam Jungmin, Park Jeongeun, Kim Kihyeun, Kang Juyoung, Yeom Gyuho. Simultaneous Detection of Infectious Diseases Using Aptamer-Conjugated Gold Nanoparticles in the Lateral Flow Immunoassay-Based Signal Amplification Platform.. Analytical chemistry. 2024. DOI: 10.1021/acs.analchem.3c04870.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.