DOI 10.1093/ptj/82.1.25

Медицинская библиотека · Physical therapy · 2002

Reliability of measurements obtained with the modified Ashworth scale in the lower extremities of people with stroke.

Blackburn Marjan, van Vliet Paulette, Mockett Simon P

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Abnormal muscle tone is a common motor disorder following stroke, which may require rehabilitation. The Modified Ashworth Scale is a 6-point rating scale that is used to measure muscle tone. The interrater and intrarater reliability of measurements obtained with the scale remain equivocal. The purpose of this study was to investigate the reliability of measurements obtained with the scale in the lower limb of patients with stroke.

SUBJECTS: Twenty patients were tested 2 weeks after their stroke, and 12 patients were tested 12 weeks after their stroke.

METHODS

Gastrocnemius, soleus, and quadriceps femoris muscles on the hemiplegic side were tested.

RESULTS

Interrater reliability for 2 raters was poor, with a Kendall tau-b correlation for the combined muscle group of.062 (P=.461). For intrarater reliability, the Kendall tau-b correlation was.567 (P<.001). The agreement within one rater occurred mostly on the grade of 0.

DISCUSSION AND

CONCLUSION

The Modified Ashworth Scale yielded reliable measurements in the lower limb for a single examiner, and agreement was best on the grade of 0. The reliability between examiners was not good, which may bring into question the validity of measurements obtained with the scale.

Для цитирования: Blackburn Marjan, van Vliet Paulette, Mockett Simon P. Reliability of measurements obtained with the modified Ashworth scale in the lower extremities of people with stroke.. Physical therapy. 2002. DOI: 10.1093/ptj/82.1.25.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.