BMC ophthalmology · 2024
Comparison of visual efficacy and patient's satisfaction between two toric IOLs, enhanced for intermediate vision and monofocal.
СтатьяСравнительное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Hwang Ho Sik, An Dohyeon, Kim Hyun Seung, Kim Eun Chul
Аннотация
BACKGROUND: To compare the visual efficacy and patient satisfaction between 2 toric IOLs (TIOL), enhanced for intermediate vision or monofocal.
METHODS: A retrospective chart review was performed of 100 eyes from 68 astigmatic patients who underwent cataract surgery with implantation of a Tecnis Eyhance Toric II IOL (Johnson & Johnson Vision, Irvine, CA, USA) (Group 1, 50 eyes) or Tecnis TIOL (Group 2, 50 eyes). The uncorrected distant (UDVA), intermediate (UIVA), and near (UNVA) visual acuities; residual refractive astigmatism; defocus curve; and IOL axis rotation were evaluated at 1 week, 1 month, 2 months, and 3 months postoperatively.
RESULTS: The postoperative UDVA and UNVA refractive astigmatism values of the two groups were better than the preoperative measurements (P < 0.05), but there was no statistical difference between the two groups (P > 0.05). The postoperative UIVA of group 1 (0.18 ± 0.15 logMAR) was significantly better than that of group 2 (0.30 ± 0.25) (P < 0.05). The mean postoperative IOL rotation of group 1 (2.51 ± 0.79°) was lower than that of group 2 (3.02 ± 0.84°) (P < 0.05). Overall satisfaction of group 1 (1.27 ± 0.47) was better than that of group 2 (2.02 ± 0.53) (P < 0.05).
CONCLUSIONS: The Tecnis Eyhance Toric II IOL demonstrated less postoperative IOL rotation and excellent uncorrected intermediate vision compared with the Tecnis TIOL. Near visual acuity and overall satisfaction with the Tecnis Eyhance Toric II IOL were also higher than those with the Tecnis TIOL.
METHODS: A retrospective chart review was performed of 100 eyes from 68 astigmatic patients who underwent cataract surgery with implantation of a Tecnis Eyhance Toric II IOL (Johnson & Johnson Vision, Irvine, CA, USA) (Group 1, 50 eyes) or Tecnis TIOL (Group 2, 50 eyes). The uncorrected distant (UDVA), intermediate (UIVA), and near (UNVA) visual acuities; residual refractive astigmatism; defocus curve; and IOL axis rotation were evaluated at 1 week, 1 month, 2 months, and 3 months postoperatively.
RESULTS: The postoperative UDVA and UNVA refractive astigmatism values of the two groups were better than the preoperative measurements (P < 0.05), but there was no statistical difference between the two groups (P > 0.05). The postoperative UIVA of group 1 (0.18 ± 0.15 logMAR) was significantly better than that of group 2 (0.30 ± 0.25) (P < 0.05). The mean postoperative IOL rotation of group 1 (2.51 ± 0.79°) was lower than that of group 2 (3.02 ± 0.84°) (P < 0.05). Overall satisfaction of group 1 (1.27 ± 0.47) was better than that of group 2 (2.02 ± 0.53) (P < 0.05).
CONCLUSIONS: The Tecnis Eyhance Toric II IOL demonstrated less postoperative IOL rotation and excellent uncorrected intermediate vision compared with the Tecnis TIOL. Near visual acuity and overall satisfaction with the Tecnis Eyhance Toric II IOL were also higher than those with the Tecnis TIOL.