MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0308830

Медицинская библиотека · PloS one · 2024

Vertical implantable collamer lens as a novel method to increase rotational stability.

Lee Yongwoo, Han Sang Beom, Auffarth Gerd U, Son Hyeck-Soo, Khoramnia Ramin, Choi Chul Young, Moon Kun, An Sang Il, Lee Je Myung, Lee Jong Ho

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: We investigated the vertical implantation of a toric implantable collamer lens (ICL) and compared the rotational stability with that of horizontal implantation.

METHODS

This matched comparative study retrospectively reviewed and analyzed data from patients who underwent ICL implantation from 2003-2022 by 1:1 matching vertical and horizontal (V and H toric groups, respectively) implantation patients according to preoperative astigmatism, spherical equivalent, sulcus-to-sulcus, anterior chamber depth, and ICL size. Visual acuity, manifest refraction, vaulting, and rotation were measured 3 months postoperatively.

RESULTS

We included 646 eyes (323 each in the V and H toric groups). No statistically significant difference was observed between groups in postoperative visual acuity, refractive error, and astigmatism. Vaulting was lower in the V toric group. (P < 0.001). The mean lens rotation in the V toric group was less than that in the H toric group (1.11 ± 2.84° versus 3.02 ± 10.34°, P = 0.001). The proportion of eyes in the V and H toric groups showing ≥10° of rotation was 2.5% (8 eyes) and 6.5% (21 eyes), respectively (P = 0.014). Despite repositioning from rotation, three (0.9%) and eight (2.5%) eyes required removal owing to lens re-rotation in the V and H toric groups, respectively.

CONCLUSION

Toric ICL vertical implantation showed good rotational stability, and appropriate visual acuity correction results with relatively low vaulting. This procedure therefore presents an effective novel method that could replace horizontal toric ICL implantation.

Для цитирования: Lee Yongwoo, Han Sang Beom, Auffarth Gerd U, Son Hyeck-Soo, Khoramnia Ramin, Choi Chul Young, Moon Kun, An Sang Il, Lee Je Myung, Lee Jong Ho. Vertical implantable collamer lens as a novel method to increase rotational stability.. PloS one. 2024. DOI: 10.1371/journal.pone.0308830.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.