MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00417-024-06586-8

Медицинская библиотека · Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2024

Assessment of the refractive outcomes of patients with regular corneal astigmatism implanted with high-power toric intraocular lenses.

Badri Yannis, Levron Antoine, Agard Emilie, Remignon Charles-Henry, Chudzinski Roman, Billant Jeremy, Bouvarel Hugo, Leroux Pierre, Fenniri Ines, Pradat Pierre, Dot Corinne

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To describe the refractive outcomes of eyes with high regular corneal astigmatism undergoing age-related cataract surgery.

METHODS

Astigmatic patients who underwent cataract surgery with implantation of high-power XY1AT HOYA® toric lenses (IOLs) (≥ T5) between March 2020 and June 2022 were included. Patients were divided into 2 groups based on the type of Total Corneal Astigmatism (TCA) used for the toric IOL calculation: group 1 = TCATK- 700 (TCA measured by the Iol Master 700®) and group 2 = TCAAK- 700 (TCA estimated from the anterior keratometry of the Iol Master 700® and using the Abulafia-Koch regression). The best-uncorrected (UDVA) and corrected (CDVA) distance visual acuity, subjective spherical equivalent (SSEq) and subjective residual cylinder (SRC) were assessed at 1 month. The predictability (centroid [CEPA] and mean absolute error in predicted astigmatism [MAEPA]) of the 2 TCA assessment methods was analyzed.

RESULTS

96 eyes of 74 patients were included. In the whole cohort, the UDVA was 0.14 ± 0.19 logMAR, the CDVA was 0.04 ± 0.07 logMAR. Postoperative SSEq was - 0.24 ± 0.53D. Postoperative SRC was - 0.48 ± 0.56D. The UDVA, SSEq and SRC did not significantly differ between groups. The MAEPA was significantly better with TCAAK-700 compared to TCATK-700: 0.58 ± 0.52D versus 0.65 ± 0.55D (p = 0.01). No significant difference was observed for the CEPA (p(x) = 0.09, p(y) = 0.19).

CONCLUSIONS

XY1AT HOYA® toric IOLs are a very good alternative even in case of high toricity. Residual astigmatism predictability is high, it would be better with TCAAK- 700. This data should be confirmed with a larger sample of patients.

Для цитирования: Badri Yannis, Levron Antoine, Agard Emilie, Remignon Charles-Henry, Chudzinski Roman, Billant Jeremy, Bouvarel Hugo, Leroux Pierre, Fenniri Ines, Pradat Pierre, Dot Corinne. Assessment of the refractive outcomes of patients with regular corneal astigmatism implanted with high-power toric intraocular lenses.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2024. DOI: 10.1007/s00417-024-06586-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.