MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40942-024-00562-4

Медицинская библиотека · International journal of retina and vitreous · 2024

Dislocated 4-haptic intraocular lens rescue with Gore-tex suture scleral re-fixation.

Michaels Luke, Moussa George, Ziaei Hadi, Davies Andrew

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Dislocated IOL exchange conventionally involves manipulation within the anterior chamber which risks secondary injury to anterior chamber structures. We describe and evaluate a 4-haptic IOL rescue technique that avoids entering the anterior chamber and thus minimizes post operative inflammation, astigmatism and recovery time relative to conventional IOL explantation and replacement techniques.

METHODS

Retrospective, non-randomized, interventional study of all patients undergoing 4-haptic IOL rescue performed by two independent vitreoretinal surgeons at a single UK centre over two years.

SURGICAL TECHNIQUE: A limited peritomy is performed with four 25-gauge scleral ports placed to enable use of two forceps, an infusion and a chandelier. A further four 27-gauge sclerotomies are symmetrically placed on the nasal and temporal sclera at 3 mm from the limbus with a 5 mm vertical separation on either side. A pars plana vitrectomy is performed followed by chandelier illuminated, bimanual cleaning of the dislocated IOL using 27-gauge serrated forceps. Gore-tex sutures are threaded through the IOL islets within the vitreous cavity and externalized through the sclerotomies for scleral re-fixation followed by conjunctival closure.

RESULTS

Seven patients underwent IOL recycling with Gore-Tex suture scleral re-fixation. All procedures were successful in repositioning the IOLs, with all patients satisfied with post-operative outcome. Mean (standard deviation) time to IOL dislocation was 13 (3) years. Median visual acuity significantly improved post-operatively from 0.85 logMAR (Interquartile Range [IQR]: 0.2-2.1) to 0.07 (0.02-0.60) logMAR (p = 0.02). No significant post-operative complications were noted apart from persistent cystoid macular oedema in one patient non-compliant with post-operative treatment.

CONCLUSIONS

Transscleral refixation using Gore-Tex suture is an effective, safe and practical approach in the management of dislocated 4-piece IOLs.

Для цитирования: Michaels Luke, Moussa George, Ziaei Hadi, Davies Andrew. Dislocated 4-haptic intraocular lens rescue with Gore-tex suture scleral re-fixation.. International journal of retina and vitreous. 2024. DOI: 10.1186/s40942-024-00562-4.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.