MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.heliyon.2024.e31867

Медицинская библиотека · Heliyon · 2024

Biometric factors associated with the postoperative visual performance of a multifocal intraocular lens.

Xu Jie, Yang Fan, Lin Peimin, Qian Dongjin, Zheng Tianyu

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To identify the biometric factors associated with postoperative visual performance after uneventful phacoemulsification with multifocal intraocular lens (MIOL) implantation.

METHODS

In this retrospective cohort study, 72 eyes of 72 patients implanted with the HumanOptics Diff-aAY MIOL were included. Preoperative examination data including the white-to-white distance (WTW), anterior chamber depth (ACD), axial length and corneal astigmatism were gathered through the electronic medical records. One month postoperatively, the pupil parameters, corneal aberrations, corneal astigmatism, IOL tilts and IOL decentrations were measured using an OPD-Scan III aberrometer. Postoperative visual performance parameters were recorded as the visual acuity, depth of focus, modulation transfer function (MTF) and point spread function (PSF) values, area under log contrast sensitivity function (AULCSF), retinal straylight and visual function questionnaire scores. Univariate and multivariate linear regression analyses were then performed to evaluate the associations between the potential biometric factors and postoperative visual outcomes.

RESULTS

Younger age predicted greater MTF and PSF values, better AULCSF and better retinal straylight (P < 0.05). A lower corneal trefoil predicted better MTF and PSF values (P < 0.05). Smaller IOL decentration predicted better distance-corrected near visual acuity, greater AULCSF and better retinal straylight (P < 0.05). A less negative spherical equivalent (SE) predicted better MTF values (P = 0.017), while a more negative SE predicted better Visual Function Index-14 (VF-14) questionnaire scores and satisfaction scores (P < 0.05). A higher IOL power predicted better best corrected distance visual acuity (P = 0.005). Lower preoperative corneal astigmatism predicted greater MTF values (P = 0.020). Lower postoperative corneal astigmatism, smaller corneal high-order aberrations (HOAs), smaller photopic pupil size, larger WTW and deeper ACD predicted a better AULCSF (P < 0.05).

CONCLUSIONS

IOL decentration, IOL power, age, preoperative and postoperative corneal astigmatism, SE, photopic pupil size, corneal trefoil, WTW, ACD and corneal HOAs were significantly associated with postoperative visual performance. These findings might aid in patient selection prior to MIOL implantation.

Для цитирования: Xu Jie, Yang Fan, Lin Peimin, Qian Dongjin, Zheng Tianyu. Biometric factors associated with the postoperative visual performance of a multifocal intraocular lens.. Heliyon. 2024. DOI: 10.1016/j.heliyon.2024.e31867.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.