MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000001435

Медицинская библиотека · Journal of cataract and refractive surgery · 2024

Biometric description of 34 589 eyes undergoing cataract surgery: sex differences.

Jiménez-García Marta, Segura-Calvo Francisco J, Puzo Martín, Castro-Alonso Francisco J, UFR-ARCCA Group Zaragoza

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To describe gender differences in the biometric parameters of a large sample of patients with cataract. Cataract surgery has evolved from a vision restoration to a refractive procedure, and population-based studies are vital to optimize normative databases and postsurgical outcomes.

SETTING

Miguel Servet University Hospital, Zaragoza, Spain.

DESIGN

Retrospective single-center observational study.

METHODS

The study included 34 589 eyes (20 004 patients with cataract). Biometric data were obtained from IOL Master 700 and Pentacam HR. Linear mixed models were used to account for intereye correlation. HofferQST formula was used to calculate the hypothetical distribution of intraocular lens (IOL) power (arbitrary lens; A = 119.2).

RESULTS

Most biometric variables showed significant differences between sexes ( P < .0001), such as 0.53 mm shorter eyes found in females, of which 0.16 mm are explained by shorter aqueous depth. Steeper anterior keratometries (∼0.75 diopter [D]) were found in women, to end up in no difference on anterior astigmatism magnitude, but different orientation ( P < .0001). The distribution of IOL power differed between sexes ( P < .001), with the interquartile range shifting 1 D toward more powerful lenses in women and odds ratio (power >26 D) = 2.26, P < .0001 (Fisher).

CONCLUSIONS

Large sample size studies provide smaller margin of error, higher power, and controlled risk of reporting false (negative or positive) findings. Highly significant differences between sexes in ocular biometry were found; this supports the idea that including sex as a parameter in IOL calculation should be explored and may improve results. In addition, the distribution of IOL powers was provided, which may be useful for manufacturers and hospital stock planning.

Для цитирования: Jiménez-García Marta, Segura-Calvo Francisco J, Puzo Martín, Castro-Alonso Francisco J, UFR-ARCCA Group Zaragoza. Biometric description of 34 589 eyes undergoing cataract surgery: sex differences.. Journal of cataract and refractive surgery. 2024. DOI: 10.1097/j.jcrs.0000000000001435.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.