Frozen Elephant Trunk Technique in a Patient with Multiple Previous Cardiac Procedures: A Case Report.

Christ Torsten, Lembcke Alexander, Laule Michael, Dohmen Pascal

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND We present the case of a 69-year-old female patient with giant aortic aneurysm who underwent previously multiple cardiac surgeries or interventions. CASE REPORT Ross procedure was performed in 2006 due to aortic valve regurgitation and aneurysm of the ascending aorta. In 2010 the patient was re-admitted for pulmonary valve insufficiency and a transcatheter pulmonary valve was implanted. Recently, the patient presented with an aortic arch aneurysm, maximum diameter 78 mm, which was treated by a hybrid approach, implanting a frozen elephant trunk and a covered stent graft. CONCLUSIONS The current case report demonstrates a suitable hybrid option for an extremely demanding procedure by multiple previous cardiac procedures.

Для цитирования: Christ Torsten, Lembcke Alexander, Laule Michael, Dohmen Pascal. Frozen Elephant Trunk Technique in a Patient with Multiple Previous Cardiac Procedures: A Case Report.. Medical science monitor basic research. 2016. DOI: 10.12659/msmbr.900105.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.