MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.echo.2014.07.002

Медицинская библиотека · Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 2014

Quantitative and pattern analyses of continuous-wave Doppler-derived pulmonary regurgitant flow velocity for the diagnosis of constrictive pericarditis.

Kaga Sanae, Mikami Taisei, Takamatsu Yuka, Abe Ayumu, Okada Kazunori, Nakabachi Masahiro, Nishino Hisao, Yokoyama Shinobu, Nishida Mutsumi, Shimizu Chikara, Iwano Hiroyuki, Yamada Satoshi, Tsutsui Hiroyuki

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Many echocardiographic features of constrictive pericarditis (CP) have been reported, but each alone has a limitation either in sensitivity or in specificity. Continuous-wave Doppler-derived flow velocity of pulmonary regurgitation can reflect the diastolic right ventricular pressure pattern characteristic of CP and be useful for its detection.

METHODS

Fifteen patients with CP, 18 patients with restrictive cardiomyopathy, and 20 normal subjects were studied retrospectively. Using continuous-wave Doppler echocardiography, pulmonary regurgitation velocities were measured at the early diastolic peak (VMAx), mid-diastolic inflection point (VIFL), and late diastolic minimal point (VMIN).

RESULTS

VIFL, VIFL/VMAx, VMIN, and VMIN/VMAx were significantly lower in the CP group compared with the restrictive cardiomyopathy and normal groups. Prevalence rates of patients with early mid-diastolic inflection, VIFL/VMAx < 0.5, VMIN < 50 cm/sec, and VMIN/VMAx < 0.33 were significantly greater in the CP group compared with the other groups. Sensitivity and specificity for the diagnosis of CP were 93% and 74%, respectively, for the presence of early mid-diastolic inflection, 73% and 100% for VIFL/VMAx < 0.5, 73% and 97% for VMIN < 50 cm/sec, and 93% and 92% for VMIN/VMAx < 0.33.

CONCLUSIONS

The quantitative and pattern analyses of continuous-wave Doppler-derived pulmonary regurgitation velocity could enhance the accuracy of echocardiographic detection of CP.

Для цитирования: Kaga Sanae, Mikami Taisei, Takamatsu Yuka, Abe Ayumu, Okada Kazunori, Nakabachi Masahiro, Nishino Hisao, Yokoyama Shinobu, Nishida Mutsumi, Shimizu Chikara, Iwano Hiroyuki, Yamada Satoshi, Tsutsui Hiroyuki. Quantitative and pattern analyses of continuous-wave Doppler-derived pulmonary regurgitant flow velocity for the diagnosis of constrictive pericarditis.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2014. DOI: 10.1016/j.echo.2014.07.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.