MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.yrtph.2022.105330

Медицинская библиотека · Regulatory toxicology and pharmacology : RTP · 2023

Plant extracts, polymers and new approach methods: Practical experience with skin sensitization assessment.

Kolle Susanne N, Flach Melanie, Kleber Marcus, Basketter David A, Wareing Britta, Mehling Annette, Hareng Lars, Watzek Nico, Bade Steffen, Funk-Weyer Dorothee, Landsiedel Robert

СтатьяПеревод пока не подготовлен

Аннотация

Over the last decade, research into methodologies to identify skin sensitization hazards has led to the adoption of several non-animal methods as OECD test guidelines. However, predictive accuracy beyond the chemical domains of the individual validation studies remains largely untested. In the present study, skin sensitization test results from in vitro and in chemico methods for 12 plant extracts and 15 polymeric materials are reported and compared to available in vivo skin sensitization data. Eight plant extracts were tested in the DPRA and h-CLAT, with the 2 out of 3 approach resulting in a balanced accuracy of 50%. The balanced accuracy for the 11 plant extracts assessed in the SENS-IS was 88%. Excluding 5 polymers inconclusive in vitro, the remainder, assessed using the 2 out of 3 approach, resulted in 63% balanced accuracy. The SENS-IS method, excluding one polymeric material due to technical inapplicability, showed 68% balanced accuracy. Although based on limited numbers, the results presented here indicate that some substance subgroups may not be in the applicability domains of the method used and careful analysis is required before positive or negative results can be accepted.

Для цитирования: Kolle Susanne N, Flach Melanie, Kleber Marcus, Basketter David A, Wareing Britta, Mehling Annette, Hareng Lars, Watzek Nico, Bade Steffen, Funk-Weyer Dorothee, Landsiedel Robert. Plant extracts, polymers and new approach methods: Practical experience with skin sensitization assessment.. Regulatory toxicology and pharmacology : RTP. 2023. DOI: 10.1016/j.yrtph.2022.105330.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.