MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/ja0658261

Медицинская библиотека · Journal of the American Chemical Society · 2006

Coupling molecular beacons to barcoded metal nanowires for multiplexed, sealed chamber DNA bioassays.

Stoermer Rebecca L, Cederquist Kristin B, McFarland Sean K, Sha Michael Y, Penn Sharron G, Keating Christine D

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

We have combined molecular beacon (MB) probes with barcoded metal nanowires to enable no-wash, sealed chamber, multiplexed detection of nucleic acids. Probe design and experimental parameters important in nanowire-based MB assays are discussed. Loop regions of 24 bases and 5 base pair stem regions in the beacon probes gave optimal performance. Our results suggest that thermodynamic predictions for secondary structure stability of solution-phase MB can guide probe design for nanowire-based assays. Dengue virus-specific probes with predicted solution-phase DeltaG of folding in 500 mM buffered NaCl of approximately -4 kcal/mol performed better than those with DeltaG > -2 or < -6 kcal/mol. Buffered 300-500 mM NaCl was selected after comparison of several buffers previously reported for similar types of assays, and 200-500 mM NaCl was found to be the optimal ionic strength for the hybridization temperatures (25 and 50 degrees C) and probe designs used here. Target binding to the surface as a function of solution concentration fit a Sips isotherm with Kd = 1.7 +/- 0.3 nM. The detection limit was approximately 100 pM, limited by incomplete quenching. Single base mismatches could be discriminated from fully complementary targets. Oligonucleotide target sequences specific for human immunodeficiency, hepatitis C, and severe acute respiratory viruses were assayed simultaneously in a no-wash, sealed chamber, multiplexed experiment in which each of three probe sequences was attached to a different pattern of encoded nanowires. Finally, we demonstrated that probe-coated nanowires retain their selectivity and sensitivity in a triplexed assay after storage for over 3 months.

Для цитирования: Stoermer Rebecca L, Cederquist Kristin B, McFarland Sean K, Sha Michael Y, Penn Sharron G, Keating Christine D. Coupling molecular beacons to barcoded metal nanowires for multiplexed, sealed chamber DNA bioassays.. Journal of the American Chemical Society. 2006. DOI: 10.1021/ja0658261.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.