Stroke · 2009
The utility of quantitative magnetic resonance angiography in the assessment of intracranial in-stent stenosis.
Письмо в редакциюНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Prabhakaran Shyam, Warrior Lakshmi, Wells Kalani R, Jhaveri Miral D, Chen Michael, Lopes Demetrius K
Аннотация
BACKGROUND AND PURPOSE: Noninvasive screening for intracranial in-stent stenosis is often limited by artifact because of the stent or associated coils. We aimed to determine the utility of quantitative MRA (QMRA) as a screening tool for detecting intracranial in-stent stenosis.
METHODS: We reviewed 14 patients who had intracranial stent placement with follow-up QMRA and conventional angiography at our institution. Socio-demographic, medical, clinical, and imaging data were abstracted from medical charts. A blinded interventional neurologist reviewed all angiograms for presence of >50% in-stent stenosis. We tested QMRA (mL/min) at varying thresholds as a predictor of angiographic results.
RESULTS: Among 14 patients (mean age, 62 years; 12 female, 2 male), 13 patients had Neuroform stents placed for wide-neck cerebral aneurysms and 1 patient had a Wingspan stent placement for atherosclerotic stenosis. Lesions were located in the intracranial internal carotid artery in 57.2% (n=8), the middle cerebral artery in 14.3% (n=2), and vertebrobasilar arteries in 28.6% (n=4). On follow-up angiography, 2 patients (14.3%) had >50% in-stent stenosis on angiography. Time-of-flight MRA was nondiagnostic in each case because of artifact from the stent or coils. A >20% reduction in vessel-specific blood flow by QMRA was associated with presence of >50% in-stent stenosis on angiography (P=0.033). As a screening tool to predict >50% angiographic in-stent stenosis, the sensitivity, specificity, positive predictive value, and negative predictive value of QMRA were 100%, 92%, 67%, and 100%, respectively.
CONCLUSIONS: We found that QMRA is a promising screening tool to detect intracranial in-stent stenosis. Future prospective studies should focus on whether QMRA has a role in the detection of radiographic restenosis and prediction of clinical events.
METHODS: We reviewed 14 patients who had intracranial stent placement with follow-up QMRA and conventional angiography at our institution. Socio-demographic, medical, clinical, and imaging data were abstracted from medical charts. A blinded interventional neurologist reviewed all angiograms for presence of >50% in-stent stenosis. We tested QMRA (mL/min) at varying thresholds as a predictor of angiographic results.
RESULTS: Among 14 patients (mean age, 62 years; 12 female, 2 male), 13 patients had Neuroform stents placed for wide-neck cerebral aneurysms and 1 patient had a Wingspan stent placement for atherosclerotic stenosis. Lesions were located in the intracranial internal carotid artery in 57.2% (n=8), the middle cerebral artery in 14.3% (n=2), and vertebrobasilar arteries in 28.6% (n=4). On follow-up angiography, 2 patients (14.3%) had >50% in-stent stenosis on angiography. Time-of-flight MRA was nondiagnostic in each case because of artifact from the stent or coils. A >20% reduction in vessel-specific blood flow by QMRA was associated with presence of >50% in-stent stenosis on angiography (P=0.033). As a screening tool to predict >50% angiographic in-stent stenosis, the sensitivity, specificity, positive predictive value, and negative predictive value of QMRA were 100%, 92%, 67%, and 100%, respectively.
CONCLUSIONS: We found that QMRA is a promising screening tool to detect intracranial in-stent stenosis. Future prospective studies should focus on whether QMRA has a role in the detection of radiographic restenosis and prediction of clinical events.
Предметные рубрики MeSH
AgedArtifactsAtherosclerosisCerebrovascular CirculationCerebrovascular DisordersConstriction, PathologicFemaleGraft Occlusion, VascularHumansIntracranial AneurysmMagnetic Resonance AngiographyMaleMiddle AgedMiddle Cerebral ArteryPredictive Value of TestsRetrospective StudiesStentsVertebrobasilar Insufficiency