MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20141113-05

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2014

Corneal hysteresis, corneal resistance factor, and intraocular pressure measurements in eyes implanted with a small aperture corneal inlay.

Agca Alper, Demirok Ahmet, Celik Haci Ugur, van de Pol Corina, Cankaya Kadir Ilker, Celik Nimet Burcu, Yasa Dilek, Yilmaz Ihsan, Yilmaz Omer Faruk

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the postoperative corneal hysteresis (CH) and corneal resistance factor (CRF) of eyes implanted with a small aperture corneal inlay versus fellow eyes.

METHODS

Medical records of patients who underwent small aperture corneal inlay (KAMRA; AcuFocus, Inc., Irvine, CA) implantation were retrospectively reviewed. There were two groups: the implanted and non-implanted. Main outcome measures were CH, CRF, Goldmann-correlated intraocular pressure (IOPg), corneal-compensated IOP (IOPcc), and Goldmann applanation tonometry measurements performed preoperatively and at postoperative week 1 and months 1, 3, and 6.

RESULTS

The study included 68 eyes of 34 patients. CH was higher in the implanted group when compared with the non-implanted group at postoperative week 1 (12.2 ± 3.1 vs 10.9 ± 1.7 mm Hg; P = .007) and month 1 (12.3 ± 2.5 vs 10.9 ± 1.8 mm Hg; P = .001). CRF was higher in the implanted group when compared with the non-implanted group at postoperative week 1 (11.9 ± 2.9 vs 10.7 ± 1.6 mm Hg; P = .003) and month 1 (12.5 ± 2.5 vs 10.4 ± 1.8 mm Hg; P < .001). IOPcc was higher in the implanted group when compared with the non-implanted group at only the first postoperative month (17.1 ± 3.5 vs 14.3 ± 2.9 mm Hg; P < .001). There were no statistically significant differences in Goldmann applanation tonometry or IOPg measurements between the two groups (P > .05). At the 3-month postoperative visit, all parameters had returned to baseline and there was no change at the 6-month visit.

CONCLUSIONS

Implantation of the KAMRA corneal inlay does not induce a permanent change in CH or CRF. A transient increase in both was seen in the early postoperative period.

Для цитирования: Agca Alper, Demirok Ahmet, Celik Haci Ugur, van de Pol Corina, Cankaya Kadir Ilker, Celik Nimet Burcu, Yasa Dilek, Yilmaz Ihsan, Yilmaz Omer Faruk. Corneal hysteresis, corneal resistance factor, and intraocular pressure measurements in eyes implanted with a small aperture corneal inlay.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2014. DOI: 10.3928/1081597x-20141113-05.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.