Gupta Isha, Oakey Zack, Stagg Brian C, Ambati Balamurali K
Аннотация
BACKGROUND: We report the case of a 40-year-old female patient treated with implantation of the Acrysof® IQ ReSTOR® lens (Alcon, Fort Worth, Tex., USA) with overlaying Acrysof EXpand® minus piggyback lens (Alcon).
METHODS: The patient had high myopia and was diagnosed with presbyopia and bilateral posterior subcapsular cataract. She desired to be spectacle-free and opted to undergo bilateral placement of the ReSTOR multifocal lens. The necessary intraocular lens (IOL) power was +3.5 in the right eye and +4.0 in the left eye, though the range of commercially available ReSTOR lenses is +6.0 to +34.0 D. In order to achieve emmetropia in this case of high myopia, it was determined that an EXpand minus piggyback lens would be necessary.
RESULTS: Implantation of the ReSTOR lens with overlaying EXpand minus piggyback lens was performed successfully and without complication. At 5 months postoperatively, the patient had 20/20 uncorrected visual acuity in both eyes. She reported a high level of satisfaction and was able to return to her daily activities including reading and driving without spectacles.
CONCLUSION: We report successful primary implantation of AcrySof EXpand minus piggyback lenses overlying the AcrySof IQ ReSTOR lens in a patient with high myopia. Long-term follow-up and further evaluation is necessary to establish piggyback IOL implantation with multifocal IOL as an accepted treatment for high myopia with presbyopia.
METHODS: The patient had high myopia and was diagnosed with presbyopia and bilateral posterior subcapsular cataract. She desired to be spectacle-free and opted to undergo bilateral placement of the ReSTOR multifocal lens. The necessary intraocular lens (IOL) power was +3.5 in the right eye and +4.0 in the left eye, though the range of commercially available ReSTOR lenses is +6.0 to +34.0 D. In order to achieve emmetropia in this case of high myopia, it was determined that an EXpand minus piggyback lens would be necessary.
RESULTS: Implantation of the ReSTOR lens with overlaying EXpand minus piggyback lens was performed successfully and without complication. At 5 months postoperatively, the patient had 20/20 uncorrected visual acuity in both eyes. She reported a high level of satisfaction and was able to return to her daily activities including reading and driving without spectacles.
CONCLUSION: We report successful primary implantation of AcrySof EXpand minus piggyback lenses overlying the AcrySof IQ ReSTOR lens in a patient with high myopia. Long-term follow-up and further evaluation is necessary to establish piggyback IOL implantation with multifocal IOL as an accepted treatment for high myopia with presbyopia.