Exploring the optimum step size for defocus curves.

Wolffsohn James S, Jinabhai Amit N, Kingsnorth Alec, Sheppard Amy L, Naroo Shehzad A, Shah Sunil, Buckhurst Phillip, Hall Lee A, Young Graeme

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the effect of reducing the number of visual acuity measurements made in a defocus curve on the quality of data quantified.

SETTING

Midland Eye, Solihull, United Kingdom.

DESIGN

Evaluation of a technique.

METHODS

Defocus curves were constructed by measuring visual acuity on a distance logMAR letter chart, randomizing the test letters between lens presentations. The lens powers evaluated ranged between +1.50 diopters (D) and -5.00 D in 0.50 D steps, which were also presented in a randomized order. Defocus curves were measured binocularly with the Tecnis diffractive, Rezoom refractive, Lentis rotationally asymmetric segmented (+3.00 D addition [add]), and Finevision trifocal multifocal intraocular lenses (IOLs) implanted bilaterally, and also for the diffractive IOL and refractive or rotationally asymmetric segmented (+3.00 D and +1.50 D adds) multifocal IOLs implanted contralaterally. Relative and absolute range of clear-focus metrics and area metrics were calculated for curves fitted using 0.50 D, 1.00 D, and 1.50 D steps and a near add-specific profile (ie, distance, half the near add, and the full near-add powers).

RESULTS

A significant difference in simulated results was found in at least 1 of the relative or absolute range of clear-focus or area metrics for each of the multifocal designs examined when the defocus-curve step size was increased (P<.05).

CONCLUSION

Faster methods of capturing defocus curves from multifocal IOL designs appear to distort the metric results and are therefore not valid.

FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.

Для цитирования: Wolffsohn James S, Jinabhai Amit N, Kingsnorth Alec, Sheppard Amy L, Naroo Shehzad A, Shah Sunil, Buckhurst Phillip, Hall Lee A, Young Graeme. Exploring the optimum step size for defocus curves.. Journal of cataract and refractive surgery. 2013. DOI: 10.1016/j.jcrs.2013.01.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.