MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2012.06.047

Медицинская библиотека · Journal of cataract and refractive surgery · 2012

Reading performance and patient satisfaction after corneal inlay implantation for presbyopia correction: two-year follow-up.

Dexl Alois K, Seyeddain Orang, Riha Wolfgang, Rückl Theresa, Bachernegg Alexander, Emesz Martin, Ruckhofer Josef, Grabner Günther

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate change in reading performance parameters after monocular Kamra corneal inlay implantation for the surgical correction of presbyopia.

SETTING

University surgical outpatient center.

DESIGN

Prospective interventional case series.

METHODS

A corneal inlay was implanted in the nondominant eye. Naturally emmetropic and presbyopic patients between 45 years and 60 years old with an uncorrected distance visual acuity of at least 20/20 in both eyes without additional ocular pathology were eligible for inclusion. Bilateral uncorrected reading acuity, reading distance, mean and maximum reading speed, and the smallest log-scaled print size (lower case letter of a Radner reading chart) were evaluated using the Salzburg Reading Desk. The minimum postoperative follow-up was 24 months.

RESULTS

Twenty-four patients were enrolled. The mean reading distance was 46.7 cm ± 6.3 (SD) preoperatively and 39.5 ± 6.4 cm 24 months postoperatively (P<.001). The mean reading acuity at best distance improved (0.33 ± 0.13 logRAD versus 0.23 ± 0.11 logRAD) (P=.004). The mean reading speed increased from 141 ± 20 words per minute (wpm) to 146 ± 20 wpm, respectively (P=.261), and the mean maximum reading speed from 171 ± 28 wpm to 180 ± 22 wpm, respectively (P=.110). The smallest print size improved from 1.50 ± 0.42 mm to 1.01 ± 0.22 mm, respectively (P<.001).

CONCLUSION

Improving the depth of focus by monocular implantation of a small-aperture optic caused statistically significant changes in all tested reading performance parameters except reading speed metrics in emmetropic presbyopic patients.

Для цитирования: Dexl Alois K, Seyeddain Orang, Riha Wolfgang, Rückl Theresa, Bachernegg Alexander, Emesz Martin, Ruckhofer Josef, Grabner Günther. Reading performance and patient satisfaction after corneal inlay implantation for presbyopia correction: two-year follow-up.. Journal of cataract and refractive surgery. 2012. DOI: 10.1016/j.jcrs.2012.06.047.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.