MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2011.08.044

Медицинская библиотека · American journal of ophthalmology · 2011

Reading performance after implantation of a modified corneal inlay design for the surgical correction of presbyopia: 1-year follow-up.

Dexl Alois K, Seyeddain Orang, Riha Wolfgang, Hohensinn Melchior, Rückl Theresa, Hitzl Wolfgang, Grabner Günther

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate change in different reading performance parameters after monocular ACI7000PDT corneal inlay implantation for the improvement of near and intermediate vision.

DESIGN

Prospective, interventional case series.

METHODS

Twenty-four patients were scheduled for corneal inlay implantation in the nondominant eye in a university outpatient surgery center. Naturally emmetropic and presbyopic patients between 45 and 60 years of age, with uncorrected distance visual acuity of at least 20/20 in both eyes, without any additional ocular pathology were eligible for inclusion. Bilateral uncorrected reading acuity, mean and maximum reading speed, and smallest log-scaled print size were evaluated with the standardized Radner Reading Charts. Measurements of reading parameters and reading distance were performed with the Salzburg Reading Desk (SRD). Minimum postoperative follow-up was 12 months.

RESULTS

The reading desk results showed significant changes in each parameter tested. After 12 months the mean reading distance changed from the preoperative value of 46.7 cm (95% CI: 44.1-49.3) to 42.8 cm (95% CI: 40.3-45.3, P < .004), and the mean reading acuity "at best distance" improved from 0.33 logRAD (95% CI: 0.27-0.39) to 0.24 logRAD (95% CI: 0.20-0.28, P < .005). Mean reading speed increased from 141 words per minute (wpm, 95% CI: 133-150) to 156 wpm (95% CI: 145-167, P < .003), maximum reading speed increased from 171 wpm (95% CI: 159-183) to 196 wpm (95% CI: 180-212, P = .001), and the smallest print size improved from 1.50 mm (95% CI: 1.32-1.67) to 1.12 mm (95% CI: 1.03-1.22, P < .001).

CONCLUSIONS

After ACI7000PDT implantation, there were significant changes in all tested reading performance parameters in emmetropic presbyopic patients. These 1-year results indicate that the inlay seems to be an effective treatment for presbyopia.

Для цитирования: Dexl Alois K, Seyeddain Orang, Riha Wolfgang, Hohensinn Melchior, Rückl Theresa, Hitzl Wolfgang, Grabner Günther. Reading performance after implantation of a modified corneal inlay design for the surgical correction of presbyopia: 1-year follow-up.. American journal of ophthalmology. 2011. DOI: 10.1016/j.ajo.2011.08.044.