MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/opth.s14325

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2011

Comparison of outcomes with multifocal intraocular lenses: a meta-analysis.

Cochener Béatrice, Lafuma Antoine, Khoshnood Babak, Courouve Laurène, Berdeaux Gilles

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the clinical outcome of different multifocal intraocular lenses (IOLs) based on information reported in the international literature.

METHODS

All comparative clinical trials that involved implanting at least one multifocal IOL in patients with cataract or presbyopia were extracted from the literature. Clinical outcomes included uncorrected near visual acuity, uncorrected distance visual acuity, visual acuity, spectacle independence, and halos. Random effects meta-analyses were conducted to compare outcomes for the different IOL types.

RESULTS

Twenty papers were identified describing 11 monofocal IOLs and 35 multifocal IOLs (19 diffractive, including 12 ReSTOR(®), 14 refractive, and two accommodative) patient cohorts. Multifocal and monofocal uncorrected distance visual acuity was 0.165 (0.090-0.240) and 0.093 (0.088-0.098), respectively. Compared with monofocal IOLs, multifocal IOLs produced better uncorrected near visual acuity (0.470 [0.322-0.618] versus 0.141 [0.131-0.152]; P < 0.0001), resulting in higher spectacle independence (incidence rate ratio [IRR] 3.62 [2.90-4.52]; P < 0.0001). Compared with refractive multifocal IOLs, diffractive multifocal IOLs produced a similar uncorrected distance visual acuity (0.105 [0.098-0.111] versus 0.085 [0.029-0.140]; P ≤ 0.78, not significant) and better uncorrected near visual acuity (0.217 [0.118-0.317] versus 0.082 [0.067-0.098]; P < 0.0001) resulting in higher spectacle independence (IRR 1.75 [1.24-2.48]; P < 0.001). Compared with other multifocal IOLs, ReSTOR produced a better uncorrected distance visual acuity (0.067 [0.059-0.076] versus 0.093 [0.088-0.098]; P < 0.0001) and better uncorrected near visual acuity (0.064 [0.046-0.082] versus 0.141 [0.131-0.152]; P < 0.006), resulting in higher spectacle independence (IRR 2.06 [1.26-1.36]; P < 0.004). Halo incidence rates with different types of multifocal implants did not differ significantly.

CONCLUSION

Multifocal IOLs provide better uncorrected near visual acuity than monofocal IOLs, leading to less need for spectacles. Multifocal IOL design might play a role in postsurgical outcome, because better results were obtained with diffractive lenses. ReSTOR showed better uncorrected near visual acuity, uncorrected distance visual acuity, and higher spectacle independence rates compared with other multifocal IOLs.

Для цитирования: Cochener Béatrice, Lafuma Antoine, Khoshnood Babak, Courouve Laurène, Berdeaux Gilles. Comparison of outcomes with multifocal intraocular lenses: a meta-analysis.. Clinical ophthalmology (Auckland, N.Z.). 2011. DOI: 10.2147/opth.s14325.