m+Medelevator.RU
← Поиск публикаций
The Japanese journal of thoracic and cardiovascular surgery : official publication of the Japanese Association for Thoracic Surgery = Nihon Kyobu Geka Gakkai zasshi · 2000

Mitral valve replacement using bileaflet mechanical prosthetic valve in the first year of life.

Клиническое исследованиеОценочное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Masuda M, Kado H, Matsumoto T, Imoto Y, Shiokawa Y, Fukae K, Ushinohama D, Yasui H

Аннотация

OBJECTIVE: The operative management and long term outcome of mitral valve replacement in infancy remain a therapeutic challenge. The selection of a prosthetic valve for this particular age group might affect the clinical outcome. Here we present our experience of mitral valve replacement in 6 infants using small bileaflet mechanical prosthetic valves.

METHODS: Between January 1994 and August 1997, 6 infants (their age ranged from 3 months to 11 months, and their body weight from 2978 g to 7403 g) underwent mitral valve replacement using a mechanical valve prosthesis (16 mm CarboMedics prosthetic valve in 5, and 17 mm St. Jude Medical prosthetic valve Hemodynamic Plus in 1). The preoperative morphological features of the mitral valve were stenosis in 1, regurgitation in 3, and a combination of these in 2. The prosthesis was fixed at the annulus in 3, and at the supra-annular position in 3. Anticoagulation was performed using warfarin.

RESULTS: There was no operative mortality. Postoperative catheterization revealed an acceptable wedge pressure in the pulmonary arteries, ranging from 10 to 12 mmHg. During the mean follow-up period of 36 months, late death due to residual pulmonary hypertension occurred in 1 patient at 10 months after surgery. Excluding this patient, all remaining patients are doing well with no need for repeated operation with no thromboembolic complication. The actuarial survival rate and the reoperation free rate at 70 months are 83 +/- 15% and 100%, respectively.

CONCLUSION: Mitral valve replacement using a small size bileaflet mechanical prosthetic valves in infancy can be performed with low operative mortality and with satisfactory mid-term results.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты