Six-month variability of the dark-adapted pupil diameter.

Khanani Arshad M, Brown Sandra M, Xu Ke Tom

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the individual variability of the dark-adapted pupil diameter over 6 months using a standardized dark-adaptation protocol.

SETTING

Texas Tech University Health Sciences Center, Lubbock, Texas, USA.

METHODS

This prospective observational cohort study comprised volunteers with no history of ocular disease, surgery, or injury other than requirement for refractive correction. The right eye was tested. A standardized dark-adaptation protocol was used that controlled for accommodation and patient alertness. Infrared, still digital photographs were taken after 10 minutes of dark adaptation at 1 lux and were analyzed using digital image software. Testing was performed at baseline in the afternoon, at 3 months in the afternoon, and at 6 months in the morning. Lifestyle factors such as diet and exercise were not controlled.

RESULTS

Mean intersession differences were 0.04 mm (95% confidence interval [CI]: -0.68-0.146), 0.15 mm (95% CI: -0.001-0.297), and 0.09 mm (95% CI: -0.048-0.236) for baseline-3 month, baseline-6 month, and 3 month-6 month comparisons, respectively. None of these differences was significantly different from zero (P>.05, 2-tailed Student t tests). The likelihood that the mean intersession difference was >.25 mm was negligible for all comparisons (P=.9996, .9099, and .9829 respectively, 1-tailed Student t tests).

CONCLUSION

When a consistent dark-adaptation protocol that controls for alertness and accommodation is used, normal young individuals showed no significant variation in the dark-adapted pupil diameter over a 6-month period.

Для цитирования: Khanani Arshad M, Brown Sandra M, Xu Ke Tom. Six-month variability of the dark-adapted pupil diameter.. Journal of cataract and refractive surgery. 2005. DOI: 10.1016/j.jcrs.2004.09.057.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.