Quality of vision following clinically successful penetrating keratoplasty.

Yagci Ayse, Egrilmez Sait, Kaskaloglu Mahmut, Egrilmez E Deniz

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate visual function following clinically successful penetrating keratoplasty (PKP).

SETTING

Department of Ophthalmology, Ege University, School of Medicine, Izmir, Turkey.

METHODS

Patient group (PG) included 9 patients (12 eyes) who had clinically successful PKP in our department. The control group (CG) included 12 people (18 eyes) who had no ocular disease other than refractive errors. Those with a visual acuity level less than 20/25 were not included in the study. Contrast sensitivity levels and light threshold values of the central retina were measured; scanning-slit corneal topography-pachymetry and aberrometric analysis were performed.

RESULTS

There were no statistical difference in terms of age (32.55 years +/- 9.25 (SD) in PG, 36.75 +/- 5.85 years in CG; P =.53), cylinder power in plus form (2.60 +/- 1.25 diopter (D) in PG, 2.79 D +/- 2.51 D in CG; P =.88), and spherical equivalent of refractive errors (-3.66 +/- 3.57 D in PG, -5.52 +/- 3.37 D in CG; P =.29) between the PG and CG. Cambridge low-contrast grating scores were 96.5 +/- 41.1 in grafted eyes and 148 +/- 27.7 in CG (P =.004). Central retinal light sensitivity was measured as 29.91 +/- 2.39 db in PG and 33.08 +/- 1.56 db in CG (P =.001). In corneal topographic analysis, mean kappa intercept was 0.69 +/- 0.37 mm in PG and 0.55 +/- 0.24 mm in CG (P =.20). Lower-order Zernike root mean squares (RMS) were 7.30 +/- 3.89 microm for PG and 8.58 +/- 3.46 microm for CG (P =.37). However, higher-order Zernike RMS were 2.15 +/- 0.78 in PG and 0.38 +/- 0.10 in CG, which is a statistically significant difference (P<.001).

CONCLUSIONS

Even though the clinically successful PKP patients have correctable amount of spherocylindrical refractive errors with spectacle lenses, they still have reduced visual quality because of the significantly high amount of higher- order aberrations when compared with naturally occurring refractive errors.

Для цитирования: Yagci Ayse, Egrilmez Sait, Kaskaloglu Mahmut, Egrilmez E Deniz. Quality of vision following clinically successful penetrating keratoplasty.. Journal of cataract and refractive surgery. 2004. DOI: 10.1016/j.jcrs.2003.10.037.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.