DOI 10.1016/j.jcrs.2003.09.060
Day to day variability of the dark-adapted pupil diameter.
Аннотация
PURPOSE: To determine the individual variability of the dark-adapted pupil diameter over 2 testing sessions using a standardized dark-adaptation protocol.
SETTING
Texas Tech University Health Sciences Center, Lubbock, Texas, USA.
METHODS
In this prospective observational cohort study, 40 volunteers with no history of ocular disease, surgery, or injury other than requirement for refractive correction were included. The right eye was tested. A standardized dark-adaptation protocol was used that controlled for accommodation and patient alertness. Infrared, still digital photographs were taken after 5 and 10 minutes of dark adaptation and analyzed independently by 2 investigators using digital-image software. Two test sessions were performed 1 to 7 days apart. Lifestyle factors such as sleep, diet, and exercise were not controlled.
RESULTS
The mean subject age was 31.5 years (range 20 to 49 years). There were 20 men; 27 subjects wore correction for myopia, and 13 wore no correction. The mean interval between test sessions was 2 days (range 1 to 7 days). The mean difference and 95% confidence intervals for pupil diameter difference between sessions were as follows: 5-minute readings, +0.032 mm (-0.030 to +0.094); 10-minute readings, -0.006 mm (-0.059 to +0.047); mean of 5- and 10-minute readings, +0.013 mm (-0.038 to +0.064). Using the paired t test, the pupil diameter did not differ significantly between sessions in 5-minute dark adaptation (P =.2980), 10-minute dark adaptation (P =.8263), or the mean (P =.6049).
CONCLUSION
Using a consistent dark-adaptation protocol that controlled for alertness, individuals aged 20 to 49 years showed no significant variation in dark-adapted pupil diameter when tested twice in 1 week.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.