MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s44211-023-00340-6

Медицинская библиотека · Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2023

Sensitive ratiometric sensor for Al(III) detection in water samples using luminescence or eye-vision.

Khairy Gasser M, Amin Alaa S, Moalla Sayed M N, Medhat Ayman, Hassan Nader

СтатьяПеревод пока не подготовлен

Аннотация

A facile, quick, and sensitive ratiometric luminescence sensor is designed for detection aluminum ions in water samples using luminescence or eye-vision. This approach relies on the emission change of the europium(III) complex with 3-(2-naphthoyl)-1,1,1,-trifluoro acetone (3-NTA) after interaction with various concentration of aluminum ions. The addition of aluminum ions suppressed the Eu(III) emission at 615 nm under 333 nm excitation, while simultaneously enhancing the ligand emission at 480 nm. Optimum detection was obtained in methanol. The quantification of aluminum ions using ratiometric method was determined by plotting the luminescence ratio (F480nm/F615nm) versus aluminum ions concentration. The calibration plot was obtained within the range 0.1-100 µM with LOD = 0.27 µM. Additionally, the concentration of aluminum ions can be estimated semi-quantitatively by visually observing the luminescence colour change of the probe from red to light green and then to dark green after being excited by a UV lamp with 365 nm. As far as we are aware, this is the first luminescent lanthanide complex-based ratiometric probe for the detection of aluminum ions. The probe showed remarkable aluminum ions selectivity relative to that of other metal ions. The suggested sensor was used effectively to identify aluminum ions in water samples with good results.

Для цитирования: Khairy Gasser M, Amin Alaa S, Moalla Sayed M N, Medhat Ayman, Hassan Nader. Sensitive ratiometric sensor for Al(III) detection in water samples using luminescence or eye-vision.. Analytical sciences : the international journal of the Japan Society for Analytical Chemistry. 2023. DOI: 10.1007/s44211-023-00340-6.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.