m+Medelevator.RU
← Поиск публикаций
The International journal of neuroscience · 2020

Remodeling of occluded internal carotid artery in vessel wall magnetic resonance imaging.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhou Jun, Cai Shi-Feng, Yuan Xian-Shun, Pang Zai-Ying, Yu Bing-Xin, Yao Hong, Xu Jing-Jing, Pang Yue-Jiu, Guo Ning, Liu Xue-Ping

Аннотация

OBJECTIVE: The purpose of the present study was to investigate the remodeling pattern of the extracranial occluded internal carotid artery (OICA) by vessel wall magnetic resonance imaging (VWI).

METHODS: Thirty-nine atherosclerotic OICAs from 32 consecutive cases underwent 3-Tesla VWI to acquire pre- and post-contrast T1-weighted two-dimensional fluid-attenuated inversion recovery fast spin echo sequences. 25 symptomatic CAs exhibited ipsilateral downstream cerebral ischemia or ophthalmic artery embolism within last three months. The 14 remaining CAs were asymptomatic. Twenty-four CAs from 22 patients with atherosclerosis but no stenosis were recruited as control group. The outer wall area (OWA) was calculated based on the outer contour of the carotid artery drawn on the pre-contrast VWI. Negative remodeling was defined as a lower OWA compared to that of control group.

RESULTS: Clinical characteristics including age, sex and vascular risk factors showed no significant difference between the occluded and control group. However, the OWA was lower in the occluded group than in the control group (0.63 versus 0.90 cm2, p = 0.004). For all OICAs, the OWA was larger in symptomatic cases than asymptomatic cases (0.71 versus 0.49cm2, p = 0.025). Using a cutoff value of 0.44, the sensitivity and specificity of OWA for detecting symptomatic OICA were 0.88 and 0.57, respectively. Heterogeneous signal intensity and enhancement were more often observed at the proximal than the distal segment of occlusion (p < 0.001). The inter-observer agreement regarding the evaluation of VWI characteristics was desirable (κ = 0.805 ∼ 0.847).

CONCLUSIONS: Negative remodeling is prevalent in OICA, especially in asymptomatic cases.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты