MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1152/japplphysiol.00416.2021

Медицинская библиотека · Journal of applied physiology (Bethesda, Md. : 1985) · 2022

High Flow Nasal Cannula compared to Continuous Positive Airway Pressure: a bench and physiological study.

Vieira Fernando, Bezerra Frank S, Coudroy Remi, Schreiber Annia, Telias Irene, Dubo Sebastian, Cavalot Giulia, Pereira Sergio Martins, Piraino Thomas, Brochard Laurent Jean

СтатьяПеревод пока не подготовлен

Аннотация

High-flow nasal cannula (HFNC) is extensively used for acute respiratory failure. However, questions remain regarding its physiological effects. We explored 1) whether HFNC produced similar effects to continuous positive airway pressure (CPAP); 2) possible explanations of respiratory rate changes; 3) the effects of mouth opening. Two studies were conducted: a bench study using a manikin's head with lungs connected to a breathing simulator while delivering HFNC flow rates from 0 to 60L/min; a physiological cross-over study in 10 healthy volunteers receiving HFNC (20 to 60L/min) with the mouth open or closed and CPAP 4cmH2O delivered through face-mask. Nasopharyngeal and esophageal pressures were measured; tidal volume and flow were estimated using calibrated electrical impedance tomography. In the bench study, nasopharyngeal pressure at end-expiration reached 4cmH2O with HFNC at 60L/min, while tidal volume decreased with increasing flow. In volunteers with HFNC at 60L/min, nasopharyngeal pressure reached 6.8cmH2O with mouth closed and 0.8cmH2O with mouth open; p<0.001. When increasing HFNC flow, respiratory rate decreased by lengthening expiratory time, tidal volume did not change, and effort decreased (pressure-time product of the respiratory muscles); at 40L/min, effort was equivalent between CPAP and HFNC40L/min and became lower at 60L/min (p=0.045). During HFNC with mouth closed, and not during CPAP, resistance to breathing was increased, mostly during expiration. In conclusion, mouth closure during HFNC induces a positive nasopharyngeal pressure proportional to flow rate and an increase in expiratory resistance that might explain the prolonged expiration and reduction in respiratory rate and effort, and contribute to physiological benefits.

Для цитирования: Vieira Fernando, Bezerra Frank S, Coudroy Remi, Schreiber Annia, Telias Irene, Dubo Sebastian, Cavalot Giulia, Pereira Sergio Martins, Piraino Thomas, Brochard Laurent Jean. High Flow Nasal Cannula compared to Continuous Positive Airway Pressure: a bench and physiological study.. Journal of applied physiology (Bethesda, Md. : 1985). 2022. DOI: 10.1152/japplphysiol.00416.2021.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.