MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1513/annalsats.202111-1280oc

Медицинская библиотека · Annals of the American Thoracic Society · 2022

Immediate Effect of Mechanical Ventilation Mode and Sedative Infusion on Measured Diaphragm Thickness.

Pearson Steven D, Lin Julie, Stutz Matthew R, Lecompte-Osorio Paola, Pohlman Anne S, Wolfe Krysta S, Hall Jesse B, Kress John P, Patel Bhakti K

СтатьяРандомизированное исследованиеПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

Rationale: In patients who are mechanically ventilated, diaphragm thinning on ultrasound is thought to correlate with diaphragm atrophy and has been associated with prolonged intubation. Factors other than atrophy, however, may cause changes in diaphragm thickness, which may confound studies examining changes in diaphragm thickness over time.

Objectives

To determine if changes in the mode of mechanical ventilation or an interruption of sedatives have immediate effects on diaphragm thickness measurements in adult patients in the intensive care unit who are mechanically ventilated.

Methods

Adult patients receiving invasive mechanical ventilation for less than 48 hours were included. Diaphragm thickness was measured at end-expiration and peak inspiration using ultrasound while patients were receiving both volume assist-control and pressure-support modes in a randomized crossover fashion. In patients receiving sedatives, additional measurements were taken after an interruption of sedatives. Measurements were compared between modes and on assist-control before and after an interruption of sedatives.

Results

Of 85 patients enrolled, 66 had measurements on assist-control and spontaneous modes, and 40 had measurements before and after an interruption of sedatives. End-expiratory diaphragm thickness increased by a median of 0.08 mm after an interruption of sedatives (95% confidence interval [CI], 0.002 mm to 0.164 mm; P = 0.017), corresponding to a median increase of 6.5%. No difference was seen when comparing measurements taken on volume assist-control and pressure support (median difference, 0 mm; 95% CI, -0.07 mm to 0.08 mm; P = 0.98).

Conclusions

End-expiratory diaphragm thickness increased by 6.5% after an interruption of sedatives. The effect of sedatives on measured diaphragm thickness should be considered in future studies examining changes in diaphragm thickness over time. Clinical trial registered with Clinicaltrials.gov (NCT04319939).

Для цитирования: Pearson Steven D, Lin Julie, Stutz Matthew R, Lecompte-Osorio Paola, Pohlman Anne S, Wolfe Krysta S, Hall Jesse B, Kress John P, Patel Bhakti K. Immediate Effect of Mechanical Ventilation Mode and Sedative Infusion on Measured Diaphragm Thickness.. Annals of the American Thoracic Society. 2022. DOI: 10.1513/annalsats.202111-1280oc.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.