MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.echo.2021.09.015

Медицинская библиотека · Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 2021

Echocardiographic Variables Associated with Transvalvular Gradient After a Transcatheter Edge-To-Edge Mitral Valve Repair.

Hadjadj Sandra, Freitas-Ferraz Afonso B, Paquin Amélie, Rouleau Zachary, Simard Serge, Bernier Mathieu, O'Connor Kim, Salaun Erwan, Pibarot Philippe, Clavel Marie-Annick, Rodés-Cabau Josep, Paradis Jean-Michel, Beaudoin Jonathan

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Transcatheter edge-to-edge mitral valve repair may lead to a reduction in mitral valve area (MVA) and elevated mean transmitral gradient (TMG). The objectives of this study were to assess the value of baseline MVA by different imaging methods and to explore the associations between MVA indexed to body surface area or left ventricular forward stroke volume and postprocedural TMG.

METHODS

Preprocedural echocardiographic images from 76 consecutive patients were retrospectively reviewed. MVA planimetry from two-dimensional (2D) transthoracic echocardiography (MVATTE), 2D transesophageal echocardiography in the transgastric view (MVA2D TEE), and three-dimensional (3D) transesophageal echocardiography (MVA3D) were measured. Postprocedural TMGs were assessed at 1 to 3 months and all-cause mortality at 1 year.

RESULTS

Postprocedural mean TMG > 5 mm Hg was associated with a 3.42-fold (95% confidence interval [CI], 1.08-10.87; P = .04) increased risk for 1-year all-cause mortality. Patients with postprocedural TMG > 5 mm Hg (25% [19 of 76]) had significantly smaller preprocedural MVA3D (3.9 ± 0.8 vs 5.2 ± 1.3 cm2, P < .01) and MVATTE (4.9 ± 1.1 vs 5.8 ± 1.5 cm2, P = .01) compared with patients without elevated TMG. No significant difference was found for MVA2D TEE (P = .20). The best threshold values for MVA3D and MVATTE to be associated with postprocedural TMG > 5 mm Hg were, respectively, 3.9 cm2 (area under the curve [AUC] = 0.80; 95% CI, 0.66-0.94; sensitivity 62%, specificity 87%) and 4.6 cm2 (AUC = 0.68; 95% CI, 0.54-0.82; sensitivity 53%, specificity 80%). MVA3D indexed to body surface area and to stroke volume showed overall the best associations with postprocedural mean TMG > 5 mm Hg, with optimal thresholds, respectively, of 2.5 cm2/m2 (AUC = 0.88; 95% CI, 0.77-0.98; sensitivity 92%, specificity 74%) and 95 cm2/L (AUC = 0.87; 95% CI, 0.77-0.97; sensitivity 85%, specificity 82%).

CONCLUSIONS

Elevated TMG following transcatheter edge-to-edge mitral valve repair was associated with increased mortality. The present results indicate that MVA3D, MVA3D indexed to body surface area, and MVA3D indexed to stroke volume may be considered potential predictors of postprocedural TMG > 5 mm Hg and could help optimize patient selection, while the use of 2D methods for valve area were poorly associated with TMG.

Для цитирования: Hadjadj Sandra, Freitas-Ferraz Afonso B, Paquin Amélie, Rouleau Zachary, Simard Serge, Bernier Mathieu, O'Connor Kim, Salaun Erwan, Pibarot Philippe, Clavel Marie-Annick, Rodés-Cabau Josep, Paradis Jean-Michel, Beaudoin Jonathan. Echocardiographic Variables Associated with Transvalvular Gradient After a Transcatheter Edge-To-Edge Mitral Valve Repair.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2021. DOI: 10.1016/j.echo.2021.09.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.