MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ogla.2020.09.005

Медицинская библиотека · Ophthalmology. Glaucoma · 2020

Predictors of Intraocular Pressure Lowering after Phacoemulsification and iStent Implantation.

Al-Holou Shaza N, Havens Shane J, Treadwell Gillian G, Ghate Deepta, Toris Carol B, Gulati Vikas

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

PURPOSE: To explore the demographic and clinical variables associated with intraocular pressure (IOP) lowering after cataract extraction (CE) alone or CE in combination with the iStent (Glaukos Corporation) placement (CE+IS).

DESIGN

Retrospective data extraction and survival analysis of consecutive patients identified over a 2-year period.

PARTICIPANTS

Patients with mild to moderate glaucoma who underwent CE (48 eyes of 32 patients) or CE+IS (61 eyes of 37 patients) were analyzed.

METHODS

Inability to reduce the number of medications or the IOP by at least 20% compared with baseline on 2 consecutive visits was considered surgical failure. Using Cox proportional hazards models, survival analysis was performed, and demographic and clinical variables were evaluated as risk factors.

MAIN OUTCOME MEASURES: Time to failure after surgical procedure.

RESULTS

CE+IS had lower odds of failure than CE alone (hazard ratio [HR], 2.01; P = 0.047). In White patients, CE+IS showed greater odds of success compared with CE alone (HR, 2.86; P = 0.007). For non-White patients, no difference was found in the outcomes for the 2 procedures (HR, 0.59; P = 0.48). In the multivariate analysis, non-White race (HR, 8.75; P = 0.0002) and longer axial length (HR, 1.61; P = 0.03) were associated with greater hazard of failure after CE+IS. In the CE group, greater odds of failure were associated with steeper corneal curvature (HR, 1.74; P = 0.008), shallower anterior chamber (HR, 0.22; P = 0.008), and longer axial length (HR, 1.58; P = 0.01).

CONCLUSIONS

Addition of the iStent to CE improved the duration of IOP lowering in White patients, but not in non-White patients. Associations between IOP lowering after CE and biometric parameters may allow for leveraging these clinical parameters for better case selection for these procedures.

Для цитирования: Al-Holou Shaza N, Havens Shane J, Treadwell Gillian G, Ghate Deepta, Toris Carol B, Gulati Vikas. Predictors of Intraocular Pressure Lowering after Phacoemulsification and iStent Implantation.. Ophthalmology. Glaucoma. 2020. DOI: 10.1016/j.ogla.2020.09.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.