MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/tvst.9.8.13

Медицинская библиотека · Translational vision science & technology · 2020

Influence of Lens Fluorescence on Fluorescence Lifetime Imaging Ophthalmoscopy (FLIO) Fundus Imaging and Strategies for Its Compensation.

Brauer Jakob Lauritz, Schultz Rowena, Klemm Matthias, Hammer Martin

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To explore the contribution of crystalline lens fluorescence to fluorescence lifetimes measured with fluorescence lifetime imaging ophthalmoscopy (FLIO) and to propose a computational model to reduce the lens influence.

METHODS

FLIO, which detects autofluorescence decay over time in a short-wavelength spectral channel (SSC, 498-560 nm) and a long-wavelength spectral channel (LSC, 560-720 nm), was performed on 32 patients before and after cataract extraction. The mean autofluorescence lifetime (τ m ) of the fundus was determined from a three-exponential fit of the postoperative fluorescence decays. The preoperative measurements were fit with series of exponential functions in which one fluorescence component was time-shifted in order to represent lens fluorescence.

RESULTS

Postoperatively, τ m was 185 ± 22 ps in the SSC and 209 ± 34 ps in the LSC at the posterior pole. These values were best reproduced by fitting the postoperative measurements with a three-exponential model with a time-shifted third fluorescence component (SSC, 203 ± 45 ps; LSC, 215 ± 29 ps), whereas disregarding time-shifted lens fluorescence resulted in significantly (P < 0.001) longer τ m values (SSC, 474 ± 206 ps; LSC, 215 ± 29 ps). The fluorescence of the cataract lens contributed to the total fluorescence by 54.2 ± 10.6% (SSC) and 29.5 ± 9.9% (LSC).

CONCLUSIONS

Cataract lens fluorescence greatly alters fluorescence lifetimes measured at the fundus by FLIO, resulting in an overestimation of the lifetimes; however, this may be compensated for considerably by taking lens influence into account in the fitting model.

TRANSLATIONAL RELEVANCE: This study investigates cataract fluorescence in FLIO and a mathematical model for compensation of this influence.

Для цитирования: Brauer Jakob Lauritz, Schultz Rowena, Klemm Matthias, Hammer Martin. Influence of Lens Fluorescence on Fluorescence Lifetime Imaging Ophthalmoscopy (FLIO) Fundus Imaging and Strategies for Its Compensation.. Translational vision science & technology. 2020. DOI: 10.1167/tvst.9.8.13.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.