MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0220498

Медицинская библиотека · PloS one · 2019

Effect of AcrySof versus other intraocular lens properties on the risk of Nd:YAG capsulotomy after cataract surgery: A systematic literature review and network meta-analysis.

Thom Howard, Ender Frank, Samavedam Saisudha, Perez Vivez Caridad, Gupta Subhajit, Dhariwal Mukesh, de Haan Jan, O'Boyle Derek

СтатьяПоддержка исследования: вне правительства СШАСистематический обзорNetwork Meta-AnalysisПеревод пока не подготовлен

Аннотация

OBJECTIVE

The purpose of this study was to evaluate the impact of different intraocular lens materials (IOL) and optic edge designs on the incidence of Nd:YAG laser capsulotomy.

METHODS

Randomized controlled trials (RCTs) reporting incidence of Nd:YAG capsulotomy in patients with monofocal IOLs were identified for systematic literature review (SLR) using Cochrane methodology. A network meta-analysis was conducted under a Bayesian framework. Mean hazard ratios (HRs), 95% credible intervals, and one-sided p-values were estimated for Nd:YAG capsulotomy incidence by comparing AcrySof IOLs with a group of non-AcrySof hydrophobic acrylic, hydrophilic acrylic, silicone, and PMMA IOLs. Sensitivity analysis was conducted comparing the risk of Nd:YAG capsulotomy between sharp- and round-edged designs of the above IOLs.

RESULTS

AcrySof IOLs had a lower risk of Nd:YAG capsulotomy compared to hydrophobic acrylic (HR: 2.68; 95% CrI: 1.41, 4.77; p < 0.01), hydrophilic acrylic (HR: 7.54; 95% CrI: 4.24, 14.06; p < 0.001), PMMA (HR: 3.64, 95% CrI: 1.87, 6.33; p < 0.001), and silicone (HR: 1.13; 95% CrI: 0.59, 1.91; p <0.1) IOLs. The risk for Nd:YAG was highest among sharp-edged IOLs for hydrophilic acrylic IOLs (HR: 9.32; 95% CrI: 4.32, 19.29; p < 0.01), followed by other hydrophobic acrylic (HR: 2.91; 95% CrI: 1.27, 5.88; p < 0.01), silicone (HR: 0.838; 95% CrI: 0.328, 1.74; p = 0.69), and PMMA (HR: 0.39; 95% CrI: 0.042, 1.49; p = 0.93) IOLs, compared to AcrySof. Acrysof IOLs had a lower risk of Nd:YAG compared to PMMA (HR: 3.25; 95% CrI: 1.21, 7.37; p < 0.01) and silicone, round edge IOLs (HR: 3.84; 95% CrI: 1.08, 10.64; p = 0.015).

CONCLUSION

The risk of Nd:YAG capsulotomy is lower in eyes implanted with AcrySof IOLs compared to non-AcrySof hydrophobic or hydrophilic acrylic IOLs. Sharp-edged AcrySof, PMMA, and silicone IOLs are comparable in terms of reducing the risk of Nd:YAG laser capsulotomy.

Для цитирования: Thom Howard, Ender Frank, Samavedam Saisudha, Perez Vivez Caridad, Gupta Subhajit, Dhariwal Mukesh, de Haan Jan, O'Boyle Derek. Effect of AcrySof versus other intraocular lens properties on the risk of Nd:YAG capsulotomy after cataract surgery: A systematic literature review and network meta-analysis.. PloS one. 2019. DOI: 10.1371/journal.pone.0220498.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.