MedElevator Войти в исследования
← Поиск публикаций

DOI 10.18240/ijo.2019.04.10

Медицинская библиотека · International journal of ophthalmology · 2019

Influence of preoperative astigmatism on corneal biomechanics and accurate intraocular pressure measurement after micro-incision phacoemulsification.

Pniakowska Zofia, Jurowski Piotr

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To define the corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg) and corneal compensated intraocular pressure (IOPcc) prior to and following coaxial micro-incision phacoemulsification in patients with corneal astigmatism.

METHODS

Of 97 patients with cataracts were enrolled in the study. Group 1 included patients with corneal astigmatism (K1-K2) values of K1-K2<+1.0 D, and group 2 with values of K1-K2 ≥+1.0 D and ≤+2.25 D. Coaxial micro-incision phacoemulsification of a corneal incision of 2.0 mm with intraocular lens (IOL) implantation was performed. CH, CRF, IOPg, IOPcc, waveform score (WS) were measured preoperatively and one week, one month postoperatively using an Ocular Response Analyzer. Axial length (AXL) was calculated by Tomey Optical Biometer OA 2000.

RESULTS

Group 1 consisted of 51 patients with mean corneal astigmatism value of +0.49±0.25 D. Group 2 included 46 patients with astigmatism of +1.43±0.43 D. In group 1, CRF (t=2.68, P<0.05), CH (t=2.64, P<0.05) and WS (t=3.51, P<0.05) were significantly lower one week postoperatively, when compared to the preoperative values. CRF significantly decreased (t=3.61, P<0.05) when measured one month following the surgery. In group 2 CH (t=5.92, P<0.05), and WS (t=3.96, P<0.05) were significantly lowered one week after cataract surgery. Moreover, we observed a significant decrease in IOPg (t=2.24, P<0.05), CRF (t=5.05, P<0.05) and CH (t=2.31, P<0.05) one month after phacoemulsification. There was no statistically significant (t=-0.83, P=0.41) difference in AXL between study groups.

CONCLUSION

CRF, CH and IOPg are reduced in patients with preoperative corneal astigmatism equal or higher than +1.0 D and lower than +2.25 D. Hence, bias of IOPg measurement in these patients may cause underestimation of the real IOP both before and after cataract surgery. The measurement of IOPcc allows the precise assessment of IOP pre- and postoperatively, independently on corneal astigmatism, CH and CRF values.

Для цитирования: Pniakowska Zofia, Jurowski Piotr. Influence of preoperative astigmatism on corneal biomechanics and accurate intraocular pressure measurement after micro-incision phacoemulsification.. International journal of ophthalmology. 2019. DOI: 10.18240/ijo.2019.04.10.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.