PURPOSE: To compare the accuracy of preoperative biometry-based formulas to intraoperative aberrometry (IA) with respect to predicting refractive outcomes after cataract surgery in short eyes.

SETTING

Private practice and community-based ambulatory surgery center.

DESIGN

Retrospective consecutive case series.

METHODS

Eyes with an axial length (AL) shorter than 22.1 mm underwent cataract extraction and intraocular lens (IOL) implantation. The predicted residual refractive error was calculated preoperatively using Hoffer Q, Holladay 2, Haigis, Barrett Universal II, and Hill-RBF formulas and intraoperatively using IA. The postoperative spherical equivalent (SE) was compared with the predicted SE to evaluate the accuracy of each aforementioned method.

RESULTS

Fifty-one eyes from 38 patients met criteria to be included in the analysis. Without optimizing the formulas specifically for short eyes, the mean numerical errors (MNEs) associated with Hoffer Q, Holladay 2, Haigis, Barrett Universal II, Hill-RBF, and IA were -0.08 (95% confidence interval [CI], -0.30 to 0.13), -0.14 (95% CI, -0.35 to 0.07), +0.26 (95% CI, 0.05 to 0.47), +0.11 (95% CI, -0.10 to 0.32), +0.07 (95% CI, -0.14 to 0.28), and +0.00 (95% CI, -0.21 to 0.21), respectively (P < .001). The proportion of eyes within ±0.5 diopter (D) of the predicted SE were 49.0%, 43.1%, 52.9%, 52.9%, 60.8%, and 58.8%, respectively (P = .06). The prediction outcomes from IA were statistically better than Haigis, but not other formulas. When formula and IA predictions differed by 0.5 D or more, IA's ability to recommend a more emmetropic outcome was no better than chance (50%).

CONCLUSIONS

Intraoperative aberrometry is not significantly different from the best preoperative biometry-based methods available for IOL power selection in short eyes.

Для цитирования: Sudhakar Shruti, Hill Darren C, King Tonya S, Scott Ingrid U, Mishra Gautam, Ernst Brett B, Pantanelli Seth M. Intraoperative aberrometry versus preoperative biometry for intraocular lens power selection in short eyes.. Journal of cataract and refractive surgery. 2019. DOI: 10.1016/j.jcrs.2018.12.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.