MedElevator Войти в исследования
← Поиск публикаций

DOI 10.31348/2018/1/1-3-2018

Медицинская библиотека · Ceska a slovenska oftalmologie : casopis Ceske oftalmologicke spolecnosti a Slovenske oftalmologicke spolecnosti · 2018

Asphercial iols and their effect on visual, depth of field, spherical aberration and contrast sensitivity.

Vlasák O, Škorpíková J, Hlinomazová Z, Kalandrová V

СтатьяПеревод пока не подготовлен

Аннотация

The work compares visual functions after cataract surgery and implantation of spherical (AAB00) and aspherical (ZCB00, MX60) intraocular lenses (IOL). The study was conducted in the years 2017-2018 at the European Eye Clinic Lexum Brno. The examined group contains 60 eyes. The study focused primarily on the comparison of distance corrected visual acuity (DCVA), the postoperative value of the total spherical aberration (SA), the depth of field (DoF) for the near and the contrast sensitivity. A single-factor ANOVA test was used for statistical analysis. Nearly all of the monitored values were statistically significantly better for the aspheric IOL group. It was DCVA (ZCB00: p = 0.048, MX60: p = 0.001), the total postoperative SA (ZCB00: p.

Для цитирования: Vlasák O, Škorpíková J, Hlinomazová Z, Kalandrová V. Asphercial iols and their effect on visual, depth of field, spherical aberration and contrast sensitivity.. Ceska a slovenska oftalmologie : casopis Ceske oftalmologicke spolecnosti a Slovenske oftalmologicke spolecnosti. 2018. DOI: 10.31348/2018/1/1-3-2018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.