Critical care (London, England) · 2025
Distribution of airway pressure opening in the lungs measured with electrical impedance tomography (POET): a prospective physiological study.
СтатьяКлиническое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Sun Nannan, Brault Clement, Rodrigues Antenor, Ko Matthew, Vieira Fernando, Phoophiboon Vorakamol, Slama Michel, Chen Lu, Brochard Laurent
Аннотация
BACKGROUND: In patients with acute hypoxemic respiratory failure (AHRF) under mechanical ventilation, the change in pressure slope during a low-flow insufflation indicates a global airway opening pressure (AOP) needed to reopen closed airways and may be used for titration of positive end-expiratory pressure.
OBJECTIVES: To understand 1) if airways open homogeneously inside the lungs or significant regional AOP variations exist; 2) whether the pattern of the pressure slope change during low-flow insufflation can indicate the presence of regional AOP variations.
METHODS: Using electrical impedance tomography, we recorded low-flow insufflation maneuvers (< 10 L/min) starting from end-expiratory positive pressure 0-5 cmH2O. We measured global (AOPglobal) and regional AOPs from pressure-impedance curves in the four different lung quadrants, and compared AOPglobal with the highest quadrantal AOP (AOPhighest). We categorized the slope change of the low-flow inflation pressure-time curve into three patterns: no change, progressive change, abrupt change.
RESULTS: Among the 36 patients analyzed, 9 (25%) had AOPglobal ≥ 5 cmH2O whereas 19 (53%) exhibited regional AOPhighest ≥ 5 cmH2O. AOPglobal was on average similar to AOP of the upper right quadrant (P = 0.182) but was lower than AOPs of the other three quadrants (P < 0.01 of each). AOPglobal was significantly lower than AOPhighest: 3.0 [2.0-4.3] vs. 5.0 [2.8-8.3] cmH2O, P < 0.001. AOP was higher in the dependent than the non-dependent ventilated lung (4.0 [2.0-6.3] vs. 3.0 [2.0-5.0] cmH2O, P < 0.001). Seventeen (47%) patients exhibited a 'progressive change' pattern in the pressure-time curve. These patients had a larger difference between AOPhighest and AOPglobal (3.0 [2.0-4.0] cmH2O with a maximum of 8 cmH2O) compared to the other two patterns: 1.0 [0-1.0] cmH2O in 'no change' , P < 0.001 and 1.0 [0-2.0] cmH2O in 'abrupt change' , P = 0.003.
CONCLUSION: AOPglobal mostly reflects the lowest opening pressure in the lung and frequently underestimates the highest regional AOP in mechanically ventilated patients with AHRF. A progressive slope change during the low-flow pressure-time curve indicates the presence of several and higher regional AOPs.
TRIAL REGISTRATION: Clinicaltrials.gov, NCT05825534 (registered, April 24th, 2023), retrospectively registered.
OBJECTIVES: To understand 1) if airways open homogeneously inside the lungs or significant regional AOP variations exist; 2) whether the pattern of the pressure slope change during low-flow insufflation can indicate the presence of regional AOP variations.
METHODS: Using electrical impedance tomography, we recorded low-flow insufflation maneuvers (< 10 L/min) starting from end-expiratory positive pressure 0-5 cmH2O. We measured global (AOPglobal) and regional AOPs from pressure-impedance curves in the four different lung quadrants, and compared AOPglobal with the highest quadrantal AOP (AOPhighest). We categorized the slope change of the low-flow inflation pressure-time curve into three patterns: no change, progressive change, abrupt change.
RESULTS: Among the 36 patients analyzed, 9 (25%) had AOPglobal ≥ 5 cmH2O whereas 19 (53%) exhibited regional AOPhighest ≥ 5 cmH2O. AOPglobal was on average similar to AOP of the upper right quadrant (P = 0.182) but was lower than AOPs of the other three quadrants (P < 0.01 of each). AOPglobal was significantly lower than AOPhighest: 3.0 [2.0-4.3] vs. 5.0 [2.8-8.3] cmH2O, P < 0.001. AOP was higher in the dependent than the non-dependent ventilated lung (4.0 [2.0-6.3] vs. 3.0 [2.0-5.0] cmH2O, P < 0.001). Seventeen (47%) patients exhibited a 'progressive change' pattern in the pressure-time curve. These patients had a larger difference between AOPhighest and AOPglobal (3.0 [2.0-4.0] cmH2O with a maximum of 8 cmH2O) compared to the other two patterns: 1.0 [0-1.0] cmH2O in 'no change' , P < 0.001 and 1.0 [0-2.0] cmH2O in 'abrupt change' , P = 0.003.
CONCLUSION: AOPglobal mostly reflects the lowest opening pressure in the lung and frequently underestimates the highest regional AOP in mechanically ventilated patients with AHRF. A progressive slope change during the low-flow pressure-time curve indicates the presence of several and higher regional AOPs.
TRIAL REGISTRATION: Clinicaltrials.gov, NCT05825534 (registered, April 24th, 2023), retrospectively registered.