IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026

A Minimalist, Foot-Mounted IMU Approach to Parkinson's Disease Detection in Semi-Controlled Settings.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gascon Alberto, Marco Alvaro, Herrero Pablo, Casas Roberto, Cruz Natalia Brandin-de la, Blanco Teresa, Perez-Palomares Sara, Buldain David, Gil-Calvo Marina, Gomez-Trullen Eva Maria, Lapuente-Hernandez Diego, Calvo Sandra

Аннотация

Scalable tools for Parkinson's disease (PD) detection are needed beyond laboratory-bound assessments. We present and evaluate a deliberately minimalist approach: a single six-axis IMU per shoe coupled with a lightweight 1D-CNN, tested during a six-minute walk test (6MWT) conducted indoors and outdoors under semi-controlled conditions. Eighty-nine participants (44 PD; 45 healthy controls) were instrumented bilaterally at 50 Hz. Signals (accelerometer and gyroscope) were standardized to a common shoe-referenced frame and ingested as raw time series using 0.5-s non-overlapping windows. The network used three tapered convolutional blocks (32-16-8 filters) with global average pooling (2,818 parameters). Evaluation employed participant-level, stratified 5-fold cross-validation repeated across seeds. At the foot level, overall accuracy was 80.58% (sensitivity 74.76%, specificity 85.55%). Applying a clinically motivated one-foot-positive criterion (OFPC), classifying a participant as PD if either foot was positive, improved patient-level performance to 82.1% accuracy, with 84.78% sensitivity and 80.29 specificity. Indoor performance (accuracy 81.48%, sensitivity 91.89%, specificity 72.73%,) exceeded outdoor sensitivity, whereas outdoor testing maintained higher specificity (accuracy 82.17%, sensitivity 80%, specificity 83.91%), reflecting expected context variability. Compact architecture and short, non-overlapping windows minimize memory, computation and latency, supporting on-device deployment on resource-constrained wearables. These results indicate that a foot-mounted, single-modality IMU set-up combined with a compact CNN can deliver clinically meaningful PD discrimination under ecologically relevant conditions, providing a practical pathway toward real-time case identification and follow-up in routine care while preserving scalability and usability.