[Application of artificial intelligence-based organ contouring software and comparison of results in treatment planning for radiotherapy].

Bungyi Gergely, Pócza Tamás, Zongor Ágnes, Takácsi-Nagy Zoltán, Major Tibor

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

Introduction

The first step in the radiotherapy treatment of cancer patients is the treatment planning, which involves delineations of the target volume (tumour) and organs at risk on a series of CT scans. This process is called contouring or segmentation. The delineation is performed in two dimensions on axial CT slices, but the dose distribution calculation and plan evaluation are carried out in three dimensions. Contouring has traditionally been done manually, but automatic organ contouring software are now available to make the process more accurate and consistent.

Objective

To compare the quality of contouring software using artificial intelligence-based algorithms, and to define the organs that can be outlined with the best consistency, and those organs where there are large differences in segmentation between different software. Method: Contours of organs at risk defined by three contouring software (MVision, ART-Plan, Limbus) in four anatomical regions on a series of 93 CT scans were compared. MVision contours were the references, and contours defined by the two systems were compared with them based on volumes, centers of mass location, and spatial similarity and conformity indices. We ranked the spatial similarity, defining the organs with the smallest and largest differences.

Results

Order of the organs with the best agreement: lungs, brain, liver, spleen, stomach, heart, eyes, mandible, kidneys, spinal cord, breasts, and bladder. The largest deviations were found at small-volume organs: thyroid, chiasma, left anterior descending artery, and pituitary. Large variations were found in the prostate and differences in the trachea were due to different interpretations of the anatomical boundaries. Discussion: For organs where the tissue density differs significantly from their surroundings (air–soft tissue, bone–soft tissue), the software can determine the organ in question with the appropriate quality. Small differences in contours were found for larger and relatively large differences for smaller organs.

Conclusions

The contours were defined with good agreement by the software for most of the organs, large deviations were found only in small-volume organs. Orv Hetil. 2024; 165(49): 1934–1944.

Для цитирования: Bungyi Gergely, Pócza Tamás, Zongor Ágnes, Takácsi-Nagy Zoltán, Major Tibor. [Application of artificial intelligence-based organ contouring software and comparison of results in treatment planning for radiotherapy].. Orvosi hetilap. 2024. DOI: 10.1556/650.2024.33180.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.