MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/fjc.0000000000000780

Медицинская библиотека · Journal of cardiovascular pharmacology · 2020

Pulmonary Delivery of Metoprolol Reduces Ventricular Rate During Atrial Fibrillation and Accelerates Conversion to Sinus Rhythm.

Marum Alexandre A, Araujo Silva Bruna, Bortolotto Alexandre L, Pedreira Giovanna C, Tessarolo Silva Fernanda, Medeiros Sofia A, Nearing Bruce D, Belardinelli Luiz, Verrier Richard L

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Safe, effective pulmonary delivery of cardioactive agents in humans is under development.

OBJECTIVES

We examined whether intratracheal delivery of metoprolol can reduce ventricular rate during atrial fibrillation (AF) and accelerate conversion to sinus rhythm.

METHODS

In 7 closed-chest, anesthetized Yorkshire pigs, AF was induced by intrapericardial infusion of acetylcholine (1 mL of 102.5-mM solution) followed by atrial burst pacing and was allowed to continue for 2 minutes before intratracheal instillation of sterile water or metoprolol (0.2-mg/kg bolus) using a catheter positioned at the bifurcation of the main bronchi. High-resolution electrograms were obtained from catheters fluoroscopically positioned in the right atrium and left ventricle.

RESULTS

Rapid intratracheal instillation of metoprolol caused a 32-beat/min reduction in ventricular rate during AF (from 272 ± 13.7 to 240 ± 12.6 beats/min, P = 0.008) and a 2.3-minute reduction in AF duration (from 10.3 ± 2.0 to 8.0 ± 1.4 minutes, P = 0.018) compared with sterile water control. Conversion of AF to sinus rhythm was associated with rapid restoration (5-6 minutes) of heart rate and arterial blood pressure toward control values. Intratracheal metoprolol reduced AF dominant frequency by 31% (from 8.7 ± 0.9 to 6.0 ± 1.1 Hz, P = 0.04) compared with control and resulted in a trend toward a 5% increase in PR interval (from 174 ± 11.2 to 182 ± 11.4 ms, P = 0.07).

CONCLUSIONS

Intratracheal delivery of metoprolol effectively reduces ventricular rate during AF and accelerates conversion to normal sinus rhythm in a pig model of acetylcholine-induced AF.

Для цитирования: Marum Alexandre A, Araujo Silva Bruna, Bortolotto Alexandre L, Pedreira Giovanna C, Tessarolo Silva Fernanda, Medeiros Sofia A, Nearing Bruce D, Belardinelli Luiz, Verrier Richard L. Pulmonary Delivery of Metoprolol Reduces Ventricular Rate During Atrial Fibrillation and Accelerates Conversion to Sinus Rhythm.. Journal of cardiovascular pharmacology. 2020. DOI: 10.1097/fjc.0000000000000780.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.