DOI 10.5692/clinicalneurol.cn-001990
[A case of amyotrophic lateral sclerosis managed by tracheostomy and invasive ventilation in which air leaks occurred at the cuff].
Аннотация
The patient was a 64-year-old woman who had been diagnosed with amyotrophic lateral sclerosis 8 years ago, and had been under artificial ventilation with tracheotomy for 6 years. Computed tomography indicated a dilated tracheal diameter of 29.6 mm at the cuff, and a high cuff pressure of 80 cmH2O. An adjustable flange tracheostomy tube with an optional length setting was used to extend the effective length by 28 mm. A previously evident air leak disappeared with the change in cuff level, and cuff pressure decreased to 25 cmH2O. X-ray images indicated a reduction in the size of the previous cuff area. Tracheal dilatation due to improper management of cuff pressure is a contributing factor to air leakage at the cuff area, and using an adjustable flange tracheostomy tube in an effort to resolve such air leaks is a valid option.