DOI 10.1097/j.jcrs.0000000000001912
Impact of pupil size on defocus curve, contrast sensitivity, and patient satisfaction in a diffractive, simultaneous vision intraocular lens.
Аннотация
PURPOSE: To evaluate the relationship between pupil size (PS) and defocus curve, contrast sensitivity (CS), spectacle independence, and patient satisfaction after implantation of a diffractive, simultaneous vision intraocular lens (SVL; AcrySof IQ PanOptix).
SETTING
Department of Ophthalmology, Goethe-University, Frankfurt, Germany.
DESIGN
Post hoc analysis of prospective studies.
METHODS
Patients were included 3 months after bilateral implantation of a diffractive SVL. Exclusion criteria included any ocular pathologies or previous ocular surgeries besides cataract or refractive lens exchange. Monocular defocus curve and infrared-based pupillometry (PupilX) in mesopic (MC) and photopic conditions (PC) and binocular visual acuity (VA) in various distances, CS, satisfaction in daily activities (driving day/night, TV, theater, home, PC, newspaper, cooking, and domestic work), and spectacle independence for distance, intermediate, and near were obtained. PS was analyzed continuously and categorized in small (≤4 mm [MC]; ≤2.5 mm [PC]), medium (>4 to 5 mm [MC]; >2.5 to 4 mm [PC]), and large (>5 mm [MC]; >4 mm [PC]).
RESULTS
52 patients (mean age 68 years) were included. 3 months postoperatively, PS was 4.24 (2.60 to 6.10) mm in MC and 3.38 (1.20 to 5.60) mm in PC. Besides correlations with extreme ends of the defocus curve, especially photopic PS weakly correlated with near-visual and partially with the intermediate range. Smaller photopic PS led partially to more near-spectacle independence. Photopic and mesopic PS moderately correlated with range of depth-of-field (RoF) ≤0.2 and 0.3 logMAR. Smaller pupils yielded better VA across the defocus curve, bigger RoF, and a trend of being more satisfied with newspaper reading. In the other parameters, PS was not significant.
CONCLUSIONS
PS especially affected the near-visual range, near-spectacle independence, and RoF in a diffractive, SVL.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.