Frontiers in medicine · 2026
Clinical outcomes after mix-and-match implantation of monofocal and refractive multifocal intraocular lenses after surgery.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Xing Ying, Li Fuqiang, Wang Yaru, Ma Zengfei, Wang Zengjie, Zhang Hui
Аннотация
PURPOSE: To analyze the visual acuity, visual quality, and stereoscopic function of patients with binocular cataracts following mixed refractive multifocal intraocular lens (MIOL) (Lentis Comfort LS-313 MF15; Oculentis GmbH, Germany) and monofocal IOL (Tecnis ZCB00; Johnson & Johnson Vision, USA) implantation.
SETTING: The study was conducted at the Eye Center of our hospital between January 2023 and December 2023.
DESIGN: This was a retrospective, case-control study.
METHODS: This retrospective study compared mixed implantation (LS-313 MF15 in non-dominant eye + ZCB00 in dominant eye, n = 30) versus bilateral monofocal implantation (ZCB00, n = 30). Visual acuity (uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA)), defocus curves, stereopsis, and patient-reported outcomes were assessed at 3 months.
RESULTS: Sixty patients (120 eyes) were enrolled. Group A exhibited significantly better UIVA (p < 0.001) and UNVA (p < 0.001) than Group B. The defocus curve indicated more continuous visual acuity in Group A, which had a significantly better postoperative VF-14 (Visual Function Index-14) score (p < 0.001) and spectacle independence rate than Group B. Near-stereoscopic acuity measured using Titmus card showed clearer stereoscopic vision in Group A than in Group B, with a significant difference (p < 0.001).
CONCLUSION: Hybrid monovision may be an effective approach for patients with binocular cataracts since the concept of partial monovision is well-suited for the desire of eyeglass independence.
SETTING: The study was conducted at the Eye Center of our hospital between January 2023 and December 2023.
DESIGN: This was a retrospective, case-control study.
METHODS: This retrospective study compared mixed implantation (LS-313 MF15 in non-dominant eye + ZCB00 in dominant eye, n = 30) versus bilateral monofocal implantation (ZCB00, n = 30). Visual acuity (uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA)), defocus curves, stereopsis, and patient-reported outcomes were assessed at 3 months.
RESULTS: Sixty patients (120 eyes) were enrolled. Group A exhibited significantly better UIVA (p < 0.001) and UNVA (p < 0.001) than Group B. The defocus curve indicated more continuous visual acuity in Group A, which had a significantly better postoperative VF-14 (Visual Function Index-14) score (p < 0.001) and spectacle independence rate than Group B. Near-stereoscopic acuity measured using Titmus card showed clearer stereoscopic vision in Group A than in Group B, with a significant difference (p < 0.001).
CONCLUSION: Hybrid monovision may be an effective approach for patients with binocular cataracts since the concept of partial monovision is well-suited for the desire of eyeglass independence.