m+Medelevator.RU
← Поиск публикаций
Diagnostics (Basel, Switzerland) · 2026

Modeling the Influence of Large Particles on Optical Properties of Nuclear Cataracts: Insights from Enhanced LOCS III-Based Computational Analysis.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lee Chi-Hung, Chen Yu-Jung, Chuang Yung-Chi, Woo George C, Lin Fen-Chi, Huang Shuan-Yu

Аннотация

Background: Nuclear cataracts cause visual degradation through light scattering by aggregated proteins and particles within the crystalline lens. Existing computational models mainly consider submicron scatterers, while the optical impact of micrometer-scale particles observed in human nuclear cataracts remains underexplored. Objective: This study extends a LOCS III-based computational cataract model by incorporating micrometer-scale particles and quantitatively evaluates their effects on forward and backward light scattering across nuclear cataract grades. Methods: A physics-based scattering model was implemented using optical simulation software (LightTools). Three particle populations-nanometer-scale (S-type), submicron-scale (M-type), and micrometer-scale (L-type)-were uniformly distributed within the lens. Retinal luminance reduction was analyzed for forward scattering, while slit-lamp-based backward scattering simulations were used to evaluate luminance distributions and chromaticity changes. Particle concentrations were varied within clinically reported ranges corresponding to LOCS III grades. Results: Micrometer-scale particles had minimal impact in early nuclear cataract grades but significantly increased forward scattering and luminance loss in advanced grades (NO5-NO6). Backward scattering simulations revealed pronounced luminance enhancement and yellow chromaticity shifts with increasing micrometer-scale particle concentration. One micrometer-scale particle produced a luminance-reduction effect equivalent to approximately 6-7 submicron particles, depending on cataract severity. Conclusions: Including micrometer-scale particles enables a more complete optical representation of nuclear cataracts, linking retinal image degradation with slit-lamp appearance. The model provides a physically grounded framework for offline analysis and reference data generation to support clinical interpretation of cataract grading.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты