m+Medelevator.RU
← Поиск публикаций
Advances in ophthalmology practice and research · 2025

Comparison of the accuracy of six intraocular lens power calculation methods in post-myopic-LASIK eyes.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yang Qingying, He Wenwen, Cheng Kaiwen, Meng Jiaqi, Zhu Xiangjia

Аннотация

OBJECTIVES: To compare the accuracy of six intraocular lens (IOL) power calculation methods in post-myopic-LASIK eyes.

METHODS: Post-myopic-LASIK patients scheduled for cataract surgery were enrolled. Mean error (ME), mean absolute error (MAE), and median absolute error (MedAE) of ASCRS (ASCRS-Max, ASCRS-Average, ASCRS-Min), EVO 2.0, Pearl-DGS, Barrett True-K no-history, Shammas-PL, and Haigis-L were compared. The ASCRS method employed four formulas, including Shammas-PL, Haigis-L, Potvin-Hill Pentacam, and Barrett True-K no-history. Trueness, precision, and accuracy indices were evaluated by comparing trimmed-mean values with heteroscedasticity adjustment. Subgroup analyses were performed based on K value, axial length (AL), and corneal decentered ablation, respectively. Factors influencing prediction errors were analyzed.

RESULTS: Totally, 87 eyes were analyzed. ASCRS-Min had the lowest MAE (0.79 D) and MedAE (0.62 D), followed by EVO 2.0, Pearl-DGS, and Barrett True-K no-history. It also had the highest percentage of absolute errors within 1.00 D. All methods outperformed ASCRS-Max in accuracy indices, and ASCRS-Min and EVO 2.0 showed superior accuracy indices compared to Shammas-PL and Haigis-L. In the subgroups of lower K value, longer AL, and larger decentration of ablation zone, ASCRS-Min, EVO 2.0, Pearl-DGS, and Barrett True-K no-history generated statistically lower MedAEs than ASCRS-Max. The accuracy of Shammas-PL was associated with AL; the accuracy of Haigis-L was associated with K value and AL; no other significant associations were found.

CONCLUSIONS: Generally, ASCRS-Min, EVO 2.0, Pearl-DGS, and Barrett True-K no-history achieve relatively better accuracy than the other methods, which might be considered as first choices for IOL power calculation in post-myopic-LASIK eyes.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты