m+Medelevator.RU
← Поиск публикаций
Journal of cataract and refractive surgery · 2026

Enhancing visibility and efficiency in toric intraocular lens surgery with the pivot technique and an assistant-mounted guidance system.

СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Noguchi Santaro, Nakakura Shunsuke, Noguchi Asuka

Аннотация

PURPOSE: To evaluate surgical outcomes and visibility when mounting the Verion guidance system on the assistant microscope compared with the main microscope during toric intraocular lens (IOL) implantation.

SETTING: ASUCA Eye Clinic, Sendai, Miyagi, Japan.

DESIGN: Experimental study and retrospective observational study.

METHODS: The influence of the Verion guidance system on surgical field image quality was evaluated in porcine eyes through luminance analysis in ImageJ. The clinical study included 201 eyes with grade 2 nuclear cataracts. Axis marking was performed with the guidance system mounted on the assistant microscope using the pivot technique (pivot group; n = 105) or on the main microscope using the conventional technique (conventional group; n = 96). The primary outcome was IOL rotational stability at 3 months postoperatively. Secondary outcomes included surgical time, visual acuity, and refractive results.

RESULTS: The guidance system significantly reduced overall image brightness (mean luminance: 55.4 ± 15.4 vs 84.8 ± 17.7) and obscured fine details. The pivot and conventional groups had no significant difference in absolute toric IOL misalignment at 3 months ( P = .819). Surgical time was shorter in the pivot group (226.8 ± 105.4 seconds vs 233.6 ± 119.2 seconds; P = .024). Postoperative visual and refractive outcomes were comparable ( P > .05) with no serious complications.

CONCLUSIONS: The pivot technique achieved comparable IOL rotational stability and visual outcomes vs the conventional method. By circumventing light reduction induced by the guidance system, the pivot technique represents a safe, useful, and efficient alternative in toric IOL implantation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты