Comparison of the diagnostic and prognostic abilities of flexible laryngoscopy and dynamic digital radiography for vocal cord paralysis: A prospective observational study.

Shibuya Yukimi, Hirano Koichi, Miyamoto Makoto, Mitsuma Tomoya, Nakazato Yoko, Matsutani Noritsugu, Tanaka Ryota, Machida Haruhiko, Kondo Haruhiko

СтатьяСравнительное исследованиеНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Although flexible laryngoscopy (FL) is the reference modality for diagnosing vocal cord paralysis (VCP), FL involves patient discomfort and insertion intolerance. Dynamic digital radiography (DDR) with high spatial and temporal resolution is easier to use and less invasive when evaluating VCP.

METHODS

Seventy-eight patients underwent FL and DDR before and after neck surgery. Qualitative and quantitative vocal cord movement (VCM) evaluations were conducted. Patients with postoperative VCP were followed-up regularly.

RESULTS

DDR exhibited diagnostic performance with 67% sensitivity and 100% specificity. The cutoff for VCM was 2.4 mm, with DDR exhibiting 100% sensitivity and 78% specificity. All cords with transient VCP had positive VCM at both 3 weeks and 2 months. Additionally, 50% and 75% of cords with permanent VCP had negative VCM at 3 weeks and 2 months, respectively.

CONCLUSIONS

DDR is promising for the diagnosis of postoperative VCP and early prediction of permanent postoperative VCP.

Для цитирования: Shibuya Yukimi, Hirano Koichi, Miyamoto Makoto, Mitsuma Tomoya, Nakazato Yoko, Matsutani Noritsugu, Tanaka Ryota, Machida Haruhiko, Kondo Haruhiko. Comparison of the diagnostic and prognostic abilities of flexible laryngoscopy and dynamic digital radiography for vocal cord paralysis: A prospective observational study.. Head & neck. 2024. DOI: 10.1002/hed.27756.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.