MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jstrokecerebrovasdis.2016.06.005

Медицинская библиотека · Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association · 2016

Arterial Spin-Labeling Magnetic Resonance Perfusion Imaging with Dual Postlabeling Delay in Internal Carotid Artery Steno-occlusion: Validation with Digital Subtraction Angiography.

Akiyama Tomoaki, Morioka Takato, Shimogawa Takafumi, Haga Sei, Sayama Tetsuro, Kanazawa Yuka, Murao Kei, Arakawa Shuji

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Arterial spin-labeling magnetic resonance perfusion imaging (ASL-MRI) allows noninvasive measurement of cerebral blood flow (CBF) but depends on the arterial transit time (ATT). With the commonly used single postlabeling delay (PLD) of 1.5 seconds, slow flow through collateral vessels may be underestimated. We used both 1.5 and 2.5 seconds to overcome this problem. We validated these PLD settings by measuring the ATT and identifying the angiographic circulation using digital subtraction angiography (DSA).

METHODS

We retrospectively selected 5 patients with unilateral occlusion or stenosis of the internal carotid artery (ICA) in whom ASL-MRI showed low CBF with 1.5-second PLD in the target area and improved CBF with 2.5-second PLD. We then compared the ASL-MRI findings visually with DSA findings at 1.5 and 2.5 seconds after injection of the contrast. When arterial transit artifacts (ATAs), attributed to stagnant intravascular spin-labeled blood, were observed, DSA findings were analyzed visually at 4.5 seconds.

RESULTS

DSA revealed that the hypovascular area seen at 1.5 seconds was improved via the primary and secondary collaterals and delayed anterograde flow at 2.5 seconds. Serpiginous or round-shaped ATAs, which appeared in nearly the same configuration on dual PLD ASL-MRI, were attributed to stagnant collaterals and flow in the M2 portion of the middle cerebral artery and ICA during the late venous phase.

CONCLUSIONS

Use of dual PLD times was validated by the DSA findings. ATA detection using the dual PLDs also differentiated well-developed and stagnant collateral vessels from focal hyperperfusion.

Для цитирования: Akiyama Tomoaki, Morioka Takato, Shimogawa Takafumi, Haga Sei, Sayama Tetsuro, Kanazawa Yuka, Murao Kei, Arakawa Shuji. Arterial Spin-Labeling Magnetic Resonance Perfusion Imaging with Dual Postlabeling Delay in Internal Carotid Artery Steno-occlusion: Validation with Digital Subtraction Angiography.. Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association. 2016. DOI: 10.1016/j.jstrokecerebrovasdis.2016.06.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.