Thrombosis and haemostasis · 2008
An evaluation of methods for determining reference intervals for light transmission platelet aggregation tests on samples with normal or reduced platelet counts.
Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Hayward Catherine P M, Moffat Karen A, Pai Menaka, Liu Yang, Seecharan Jodi, McKay Heather, Webert Kathryn E, Cook Richard J, Heddle Nancy M
Аннотация
Light transmission platelet aggregation tests are important for diagnosing platelet function defects. However, uncertainties exist about the best procedures to determine aggregation reference intervals. We investigated methods for determining reference intervals for light transmission aggregation tests, using the % maximal aggregation values for prospectively collected data on healthy control samples. Reference intervals for samples tested at 250 x 10(9) platelets/l were determined by mean +/- 2 standard deviations and non-parametric analyses. To establish reference intervals for tests on thrombocytopenic subjects, regression analyses were used to estimate 95% confidence limits for % maximal aggregation, according to sample platelet counts, using data for control samples diluted to match the platelet count of undiluted thrombocytopenic patient platelet-rich plasma samples. For samples tested at 250 x 10(9) platelets/l, non-parametric analyses described 95% of data for healthy control samples better than mean +/- 2 standard deviations. For samples tested at lower counts, to match thrombocytopenic samples, the % maximal aggregation was influenced by platelet count and derived limits were wider at very low platelet counts for almost all agonists. With ristocetin, it proved feasible to test samples with very low platelet counts to exclude Bernard-Soulier syndrome and type 2B von Willebrand disease. Non-parametric analyses should be the preferred method to establish light transmission aggregation reference intervals for samples tested at normal platelet counts. The derived limits for thrombocytopenic samples provide guidance for evaluating thrombocytopenic platelet function disorders, including which agonists to test, based on the sample platelet count.
Предметные рубрики MeSH
15-Hydroxy-11 alpha,9 alpha-(epoxymethano)prosta-5,13-dienoic AcidAdenosine DiphosphateArachidonic AcidBlood PlateletsCell SizeCollagenData Interpretation, StatisticalEpinephrineFeasibility StudiesHumansLightPlatelet AggregationPlatelet CountPlatelet Function TestsProspective StudiesReference ValuesRistocetinStatistics, NonparametricThrombocytopenia