Emerging technologies and quality assurance in hemostasis: a review of findings from the Royal College of Pathologists of Australasia Quality Assurance Program.

Favaloro Emmanuel J, Bonar Roslyn

СтатьяОбзорПеревод пока не подготовлен

Аннотация

Regular multilaboratory surveys of laboratories by the Royal College of Pathologists of Australasia Quality Assurance Program (QAP) have been conducted to assess proficiency in tests of hemostasis for the last 40 years. This article focuses primarily on specialized assays of hemostasis, for which surveys have been conducted for some 10 years. For von Willebrand disease (vWD) evaluations, a total of 47 plasma samples have been dispatched to survey participants, including representative samples from normal individuals plus all of the major vWD subtypes (i.e., types 1, 2A, 2B, 2M, 2N, and 3). These surveys have focused partly on the issue of diagnostic interpretive error rates associated with different assays and test panels. In this context, considerable improvement is seen when laboratories incorporate the vWF:collagen-binding assay into the test panel. Thrombophilia-associated tests assessed by the program and discussed in this review include activated protein c resistance, lupus anticoagulant, and deficiencies of protein C, protein S, and antithrombin. Other tests briefly reviewed here include factor assays and inhibitors, D-dimer, and heparin/anti-Xa assays. Anticardiolipin antibody and anti-beta(2)-glycoprotein I antibody (aB(2)GPI) testing, assessed by the Immunology QAP, is also reviewed briefly, as are genetic tests associated with thrombophilic markers such as factor V Leiden and the prothrombin gene.

Для цитирования: Favaloro Emmanuel J, Bonar Roslyn. Emerging technologies and quality assurance in hemostasis: a review of findings from the Royal College of Pathologists of Australasia Quality Assurance Program.. Seminars in thrombosis and hemostasis. 2007. DOI: 10.1055/s-2007-971809.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.