m+Medelevator.RU
← Поиск публикаций
Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis · 2006

Determination of von Willebrand factor activity: evaluation of the HaemosIL assay in comparison with established procedures.

Сравнительное исследованиеОценочное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sucker Christoph, Senft Beate, Scharf Rüdiger E, Zotz Rainer B

Аннотация

Determination of von Willebrand factor activity is required for diagnosis and classification of von Willebrand disease. In addition, von Willebrand factor activity can be of prognostic relevance in several clinical entities including thromboembolic and cardiovascular disorders in which elevated activity correlates with a poor prognosis. The HaemosIL assay (Instrumentation Laboratory GmbH, Munich, Germany) provides a new fully automated procedure for determination of von Willebrand factor activity. This assay measures binding of the von Willebrand factor to GP Ibalpha of the platelet glycoprotein complex Ib-V-IX. In our study, we analyzed 300 samples including those of patients with hereditary von Willebrand disease. The results obtained with the HaemosIL assay were compared to von Willebrand factor activities determined by established procedures. Activities determined with HaemosIL correlated with those activities determined as ristocetin cofactor (r = 0.88, p < 0.0001), collagen-binding (r = 0.93, p < 0.0001), and GP Ib-binding (r = 0.91, p < 0.0001). The comparability of results obtained by HaemosIL and the GP Ib-binding ELISA were excellent ([HaemosIL] = 0.96 infinity activity [GP Ib-binding ELISA] + 10.7), whereas activities determined by ristocetin cofactor or collagen-binding revealed more variance. Like the other assays, the HaemosIL failed to indicate a loss of high-molecular-weight von Willebrand factor multimers. The HaemosIL assay can replace the GP Ib-binding ELISA for the determination of von Willebrand factor activity. Advantages of this assay include accuracy of results, full automation, and, thus, broad availability. Since the assay does not predict the absence of high-molecular-weight multimers, multimeric analysis remains the procedure of choice for the differentiation of functional defects.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты