m+Medelevator.RU
← Поиск публикаций
Romanian journal of internal medicine = Revue roumaine de medecine interne · 2026

Forced Vital Capacity and Six-Minute Walk Test as Indicators of Interstitial Lung Disease Extent on High-Resolution Computed Tomography in Systemic Sclerosis.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Halim Sahat, Rumende Cleopas Martin, Wibowo Rm Suryo Anggoro Kusumo, Rizka Aulia, Singh Gurmeet, Azizi Mohamad Syahrir, Renaldi Kaka, Nababan Saut Horas Hatoguan, Harimurti Kuntjoro

Аннотация

INTRODUCTION: Interstitial lung disease (ILD) is a leading cause of morbidity and mortality in systemic sclerosis (SSc). High-resolution computed tomography (HRCT) is the gold standard for assessing ILD extent but is limited by cost, availability, and radiation exposure. Practical functional tools are thus needed to identify extensive ILD in routine practice.

METHODS: This cross-sectional study enrolled adult patients with SSc-associated ILD at a tertiary referral hospital in Jakarta, Indonesia. All participants underwent spirometry and the six-minute walk test (6MWT). Forced vital capacity (FVC), 6MWT distance, and exertional oxygen desaturation were evaluated. ILD extent on HRCT was classified as non-extensive (<20%) or extensive (≥20%). Associations were analyzed using bivariate analysis, receiver operating characteristic (ROC) curves, and multivariable Poisson regression with robust standard errors.

RESULTS: A total of 83 patients were included; 21 (25%) had extensive ILD. Six-minute walk test distance did not differ significantly between groups (p = 0.492; AUC 0.550). Exertional oxygen desaturation ≥4% and FVC <70% predicted were each significantly associated with extensive ILD. FVC alone achieved an AUC of 0.795, whereas adding 6MWT distance resulted in only a marginal improvement in discrimination (AUC 0.799; ΔAUC 0.005), with adequate calibration and stable internal validation.

CONCLUSION: FVC alone may serve as a practical functional indicator of ILD extent, particularly where HRCT access is limited. Routine addition of 6MWT distance is not justified solely for estimating ILD extent, although the 6MWT remains valuable for assessing functional capacity and exertional desaturation.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты